  • Page 2   FOREWORD Thank you for purchasing our generator set (hereinafter referred to as a generator). ●The copyright of the Manual is reserved to our company. ●No part of this publication may be reproduced, transmitted, distributed or stored without prior written permission of our company. ●Our company adheres to a strategy of sustainable development, so we reserve the right to make changes or improvements without notice to any product described in this publication.
  • Page 3   Safety Warnings Personal safety and property safety of you and others are very important. . Please read these messages which is preceded by a symbol carefully. You WILL be SERIOUSLY HURT if you don’t follow instructions. You CAN be SERIOUSLY HURT if you don’t follow instructions.
  • Page 4: Table Of Contents

      CONTENTS SAFETY INFORMATION................6 LOCATION OF IMPORTANT LABELS............10 DESCRIPTION...................12 Control panel …..................12 CONTROL FUNCTION................14 3 in 1 switch knob (including start/stop switch, fuel valve and chock) ....................14 Oil warning light (red)................14 Overload indicator light (Red)..............14 AC pilot light (Green) ................15 DC protector..................15 ESC switch....................16 Fuel tank cap..................16...
  • Page 5   Engine oil replacement.................33 Air filter ....................34 Muffler screen and spark Arrester............35 Fuel tank filter..................37 STORAGE....................39 Drain the fuel..................39 Engine ....................40 TROUBLESHOOTING ................40 Engine won’t start ................40 Generator won’t produce power ............41 PARAMETERS ...................41 WIRING DIAGRAM..................42 5 ...
  • Page 6: Safety Information

      SAFETY INFORMATION Read and understand this owner’s manual before operating your generator. It will help you avoid accidents if you get familiar with your generator’s safe operation procedures. Keep children and pets away from the area of operation. Never use it indoors Never directly connect it to a home power system Never use it in a wet condition...
  • Page 7   Keep it at least 1m away from Inflammables Never smoke when fueling Don’t spill when fueling 7 ...
  • Page 8   Stop the engine before fueling Connections to a Home Power RIGHT Supply If the generator is to be connected to a home power supply as a standby, connection shall be performed by a professional electrician or by another person with proficient electrical skill. When the loads are connected to the WRONG generator, please carefully check whether...
  • Page 9   Generator Ground Circuit In order to prevent electric shock due to shoddy electrical appliances or wrong use of electricity, the generator must be grounded with a good-quality insulated conductor. Ground terminal Make sure the control panel, louver and the inverter bottom side cooling well and without chips, mud and water come in.
  • Page 10: Location Of Important Labels

      LOCATION OF IMPORTANT LABELS Please read the following labels carefully before operation this machine. TIP:Maintain or replace safety and instruction labels, as necessary. ① 10 ...
  • Page 11   ②230V 50Hz ,120V 60Hz,110V 50Hz ③ ④ 11 ...
  • Page 12: Description

      DISCRIPTION ① Garrying handle ② Fuel tank cap air vent knob ③ Fuel tank cap ④ Control panel ⑤ Recoil starter ⑥ Oil filler cap ⑦ Louver ⑧ Muffler ⑨ Spark plug maintenance cover Control panel A.120V 60Hz ① Oil warning light ②...
  • Page 13   B.230V 50Hz ① Oil warning light ② Overload indicator light ③ AC pilot light ④ ESC(Engine Smart Control) in 1 switch knob ⑤ (including start/stop switch, fuel valve and chock) ⑥ AC receptacle ⑦ Parallel receptacle ⑧ Ground (earth) terminal ⑨...
  • Page 14: Control Function

      CONTROL FUNCTION 3 in 1 switch knob ① Engine switch \fuel valve “OFF”; Ignition circuit is switched off. Fuel is switched off. The engine will not run. ② Engine switch \fuel valve \ chock “ON” Ignition circuit is switched on. Fuel is switched on.
  • Page 15: Ac Pilot Light (Green)

      electric devices. The AC pilot light (Green) will go off and the overload indicator light (Red) will stay on, but the engine will not stop running. When the overload indicator light comes on and power generation stops, proceed as follows: 1.
  • Page 16: Esc Switch

    DC protector turns off. If the DC protector turns off again, stop using the device immediately and consult a LONCIN dealer. Engine smart control (ESC) ① “ON” When the ESC switch is turned to “ON”,...
  • Page 17: Ground (Earth) Terminal

    25.0 A/120V 13A /230V.) The handing, operation procedure and the notes on usage are described in the PARALLEL RUNNING KIT OWNER’S MANUAL included in the Parallel Running Kit. Consult a LONCIN dealer for this Parallel Running Kit. 17 ...
  • Page 18: Preparation

      REPARATION Fuel ·Fuel is highly flammable and poisonous. Check “SAFETY INFORMATION”(See page 1) carefully before filling. ·Do not overfill the fuel tank, otherwise it may overflow when the fuel warms up and expands. ·After fill the fuel, make sure the fuel tank cap is tightened securely.
  • Page 19: Engine Oil

      Engine oil The generator has been shipped without engine oil. Do not start the engine till fill with the sufficient engine oil. 1、Place the generator on a level surface. 2、Remove the screws①, and then remove the cover②. 3、Remove the oil filler cap③. 4、Fill the specified amount of the recommended engine oil, and then install and tighten the oil filler cap.
  • Page 20: Pre-Operation Check

    Engine oil (See page 19) Check oil level in engine. If necessary, add recommended oil to specified level. Check generator for oil leakage. The point where abnormality was recognized by use Check operation. If necessary, consult a LONCIN dealer. 20 ...
  • Page 21: Operation

      OPERATION ·Never operate the engine in a closed area or it may cause unconsciousness and death within a short time. Operate the engine in a well ventilated area. ·Before starting the engine, do not connect any electric devices. ·The generator has been shipped without engine oil.
  • Page 22   Starting the engine 1. Turn the ESC switch to “OFF” ①. 2. Turn the air vent knob to “ON” ② . 3. Turn the 3 in 1 switch to “CHOCK” ③, a. Ignition circuit is switched on. b. Fuel is switched on. c.
  • Page 23   TIP: Grasp the carrying handle firmly to prevent the generator from falling over when pulling the recoil starter. 5. After the engine starts, warm up the engine until the engine does not stop when the choke knob is returned to the “ON”...
  • Page 24: Stopping The Engine

      Stopping the engine TIP:Turn off any electric devices. 1. Turn the ESC to “OFF” ①. 2. Disconnect any electric devices. 3. Turn the 3 in 1 switch to “OFF” ②, a. Ignition circuit is switched off. b. Fuel is switched off. 4.
  • Page 25: Alternating Current (Ac) Connection

      Alternating Current (AC) connection Be sure any electric devices are turned off before plugging them in. Be sure all electric devices including the lines and plug connections are in good condition before connection to the generator. Be sure the total load is within generator rated output.
  • Page 26 To restart charging the battery, turn he DC protector on by pressing its button to “ON”. If the DC protector turns off again, top charging the battery immediately and consult a LONCIN dealer. · Follow instructions in the owner’s manual for the battery to determine the end of battery charging.
  • Page 27: Ac Parallel Operation

      AC parallel operation Before connection an appliance to either generator, make sure that it is in good working order and that its electrical rating does not exceed that of the receptacle. Most motorized appliances require more than their electrical rating for startup.
  • Page 28 Never exceed the maximum may be used for no more than 30 minutes.Never connect different generator models For parallel operation, use only a LONCIN approved parallel operation cable kit then connecting one LC2000i Companion to either an LC2000i or another LC2000i Companion generator.
  • Page 29: Application Range

      Application range When using the generator, make sure the total load is within rated output of a generator. Otherwise, generator damage may occur Power 0.4-0.75 0.8-0.95 factor (Efficiency 0.85) Rated voltage 12v LC2000i ~1,600W ~1,280W ~544W Rated current8.3A · “~”means below. ·...
  • Page 30: Periodic Maintenance

    The most important points of generator inspection, and lubrication are explained on the following pages. If you are not familiar with maintenance work, have a LONCIN dealer do it for Maintenance chart Stop the engine before starting maintenance work.
  • Page 31: Spark Plug Inspection

      Every Preoper Item Routine ation months month check or 100 s or 300 Hr ·Check condition. ○ Spark plug ·Clean and replace if necessary. ·Check fuel level and ○ Fuel leakage. ·Check fuel hose for ○ Fuel hose cracks or damage. ·Replace if necessary.
  • Page 32 *2..The air filter element needs to be cleaned more frequently when using in unusually wet or dusty areas. ★….Since these items require tools, date and technical skills, have a LONCIN dealer perform the service. Spark plug inspection The spark plug is important engine components, which should be checked periodically.
  • Page 33: Carburetor Adjustment

    6. Install the spark plug cap and spark plug cover. Carburetor adjustment The carburetor is a vital part of the engine. Adjusting should be left to a LONCIN dealer with the professional knowledge, specialized date, and equipment to do so properly Engine oil replacement Avoid draining the engine oil immediately after stopping the engine.
  • Page 34: Air Filter

      4. Place an oil pan under the engine. Tilt the generator to drain the oil completely. 5. Replace the generator on a level surface. Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine. 6.
  • Page 35: Muffler Screen And Spark Arrester

      2. Remove the screw ③ and then remove the air filter case cover ④. 3. Remove the foam element ①. 4. Wash the foam element in solvent and dry it. 5. Oil the foam element and squeeze out excess oil. The foam element should be wet but not dripping Do not wring out the foam element when squeezing it.
  • Page 36   The engine and muffler will be very hot after the engine has been run. Avoid touching the engine and muffler while they are still hot with any part of your body or clothing during inspection or repair. 1. Remove the screws ①, and then pull outward on the areas of the cover ②...
  • Page 37: Fuel Tank Filter

      6. Install the muffler screen and the muffler cap. 7. Install the cover and tighten the screws. Fuel tank filter Never use the gasoline while smoking or in the vicinity of an open flame. 1. Remove the fuel tank cap and filter. 2.
  • Page 38   2. Hold and move up the clamp④, then take off the hose⑤ from the tank 3. Take out the fuel filter⑥ 4. Clean the filter with gasoline 5. Dry the filter and put it bank into tank 6. Install the hose and clamp, then open the fuel valve to check whether it is leak 7.
  • Page 39: Storage

      STORAGE Long term storage of your machine will require some preventive procedures to guard against deterioration. Drain the fuel 1. Turn the 3 in 1 switch to “OFF”①. 2. Remove the fuel tank cap, remove the filter . Extract the fuel from the fuel tank into an approved gasoline container using a commercially available handsiphon.Then, install the fuel tank...
  • Page 40: Engine

      6. Turn the 3 in 1 switch to “OFF”. 7. Tighten the drain screw 8. Install the cover and tighten the screws. 9. Turn the fuel tank cap air vent knob to “OFF” after the engine has completely cools down. Engine Perform the following steps to protect the cylinder, piston ring, etc.
  • Page 41: Generator Won't Produce Power

    Spark plug dirty with carbon or wet…. Remove carbon or wipe spark plug dry. Max oil level Faulty ignition system…. Consult a LONCIN dealer Min oil level Generator won’t produce power Safety device (DC protector) to “OFF”…. Press the DC protector to “ON”.
  • Page 42: 11. Parameters

      11. Parameters Model No. LC2000i Type Inverter Rated frequency /Hz 50/60/50 Rated voltage /V 230/120/110 Max. output power /kVA Rated output power /kVA Power factor Generator AC output quality ISO8528 G2 THD /% ≤5 63.5 Noise Level dB/Lpa (3/4 load、7m) DC Output / V-A 12-8.3 Non-fuse Protector...
  • Page 43: 12. Wiring Diagram

      12. WIRING DIAGRAM A. 60Hz, 120V Without Parallel Receptacle 43 ...
  • Page 44   B.60Hz,120V With Parallel Receptacle 44 ...
  • Page 45   C.50Hz,230V Without Parallel Receptacle 45 ...
  • Page 46   D.50Hz,230V With Parallel Receptacle 46 ...
  • Page 47   E.50Hz,110V With Parallel Receptacle 47 ...

Table of Contents