Page 2
Thank you for purchasing a Loncin brand generator set (hereinafter referred to as a generator). The copyright of the Manual is reserved to Loncin Industrial Co., Ltd. ● No part of this publication may be reproduced, transmitted, distributed or stored without prior written permission of Loncin Industrial Co., Ltd.
Contents Brief introduction of the generator ................... II. Safety ..........................III. Preoperation check ......................IV. Starting/stopping the generator ..................V. Use of the generator ......................VI. Maintenance of the generator ................... VII. Storage/transporting of the generator ................VIII. Troubleshooting ......................IX.
Brief introduction of the generator: Spark plug cap Fuel tank cap Fuel tank Muffler Air filter Receptacles Fuel switch Oil dipstick Starter grip Oil drain plug Engine switch...
II Safety ● Thank you very much for selecting Loncin generator, please carefully read and understand this manual before operating the generator; safe operation procedures can help you avoid accidents. The procedures to ensure safe operation: 1. Each time before starting the generator, preoperation check must be performed (see item 3 of Contents) to avoid accidents to the operators and damage to the equipment.
Page 6
Operation steps: (1) Put the generator on a horizontal ground surface. (2) Take out and wipe off the oil dipstick. Oil dipstick (3) Insert fully the dipstick and then take it out and check the oil level. Oil upper (4) If the oil level is close to or is lower than the limit lower limit mark of the dipstick, then screw off the oil...
IV. Starting/stopping the generator Steps to start the generator: 1. Cut off all loads. 2. Turn the fuel switch to the ON position. 3. Put the choke lever on the OFF position. Do not shut off the choke if the engine is started when it is warm. 4.
Before connecting the generator to the home power circuit, the circuit’s connections to external power supplies (commercial power or other power supplies) must be cut off first. 3. Earthing of the generator In order to prevent electric shock due to shoddy electrical appliances or wrong use of electricity, the generator must be earthed with a good-quality insulated conductor.
Page 9
(1) Maintain more frequently when the generator is used in dusty areas. (2) These items should be maintained by an authorized dealer of Loncin. (3) If the generator is to be used frequently, maintenance shall be performed as per the schedule above to ensure long-time normal operation.
Page 10
Engine oil may cause skin cancer if repeatedly left in contact with the skin for prolonged periods. Although the skin cancer does not necessarily happen, it is still advisable to thoroughly wash the skin that has contacted engine oil with soap and water after handling engine oil. For the sake of environment protection, please treat the used engine oil in an appropriate way.
(4) Turn the fuel valve to the ON position and check for leaks (see Figure 7). 4. Spark plug Recommended spark plugs: F7RTC or another one of the equivalent grade. (1) Remove the spark plug cap. (2) Clean any dirt from around the spark plug base. (3) Use the spark plug socket wrench to remove the spark plug.
Page 12
Gasoline is extremely inflammable and is explosive under most conditions. Perform this task in a well ventilated area with the engine stopped. Never smoke or allow flames or sparks in the area during this procedure. 2. Screw off the engine oil dipstick, and screw off the drain plug to complete drain off the engine oil of the crankcase.
VIII. Troubleshooting The following recommended troubleshooting methods are applicable to diagnosis of common malfunctions. If these methods cannot solve the problems, please contact an authorized repair station. 1. Engine Unable to start: Is there fuel in the Refill fuel tank? tank Is there enough engine oil in the crankcase?
IX.Wiring diagram 1. Wiring diagram of EN3500 Generator Overcurrent protector 12A AC receptacle Overcurrent protector Ground terminal Principal winding Control panel block Engine switch Black/White Brown connecting line Black White Green Yellow Yellow/Green Engine oil level Engine oil Blue Generator...
Page 15
2、EN5000、EN6500 电路图 Wiring diagram of N5000 and EN6500 Generators Overcurrent protector 20A AC receptacle Overcurrent protector 20A Ground terminal Principal winding Control panel block Engine switch Brown Black/White connecting line White Black Green Yellow Yellow/Green Generator block Engine Engine oil level Blue Spark plug Ignition coil level switch...
X. Basic parameters Model EN3500 EN5000 EN6500 Engine model LC168F-2 LC182F LC188F Engine type Single cylinder, 4-Stroke, OHV25°, inclined, forced air cooling Cylinder bore x 68x54 82x64 88x64 Stroke (mm) Compression 8.5:1 8.0:1 8.0:1 ratio Starting system Recoil and hand-operated Igniting mode T.C.I.