Autronica AutroFlame X33AF Instructions Manual

Autronica AutroFlame X33AF Instructions Manual

Multi-spectrum ir flame detector
Hide thumbs Also See for AutroFlame X33AF:

Advertisement

Instructions
AutroFlame X33AF
Multi-spectrum IR Flame Detector
Instructions, AutroFlame X33AF 116-P-X33AF/IGB, rev. E, 2013-08-13, Autronica Fire and Security AS
P/N 95-8625-17.1, Rev: 2/13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AutroFlame X33AF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Autronica AutroFlame X33AF

  • Page 1 Instructions AutroFlame X33AF Multi-spectrum IR Flame Detector Instructions, AutroFlame X33AF 116-P-X33AF/IGB, rev. E, 2013-08-13, Autronica Fire and Security AS P/N 95-8625-17.1, Rev: 2/13...
  • Page 2 This publication, or parts thereof, may not be reproduced in any form, by any method, for any purpose. Autronica Fire and Security AS and its subsidiaries assume no responsibility for any errors that may appear in the publication, or for damages arising from the information in it.
  • Page 3: Table Of Contents

    Table of Contents DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 FEATURES .
  • Page 5: Description

    . The Fault relay has redundant terminals and normally open contacts, normally energized operation, and latching or non-latching operation . Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 1...
  • Page 6: Led

    These features can be performed at any time and eliminate the need for testing with a non-calibrated external test lamp . Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 2...
  • Page 7: Communication

    . Data is accessible using the RS-485 port . Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 3...
  • Page 8: General Application Information

    . It should not be used to detect fires from fuels that do not contain carbon, such as hydrogen, sulfur, and burning metals . Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 4...
  • Page 9: Installation

    D1974 NOTE: DETECTOR MUST ALWAYS BE AIMED DOWNWARD AT LEAST 10 TO 20 DEGREES. Figure 1—Detector Orientation Relative to Horizon Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 5...
  • Page 10: Wiring Procedure

    (10.2) 10.6 (27.0) E2069 Figure 3—Q9033 Mounting Bracket Dimensions in Inches (cm) (See Figure 1 for Correct Detector Orientation .) Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 6...
  • Page 11 3 . Make the final sighting adjustments and use a 14 mm hex wrench to ensure that the mounting arm assembly is tight . Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 7...
  • Page 12 Figure 5—X33AF Wiring Terminal Identification 3/8 INCH (10 MM) GAP MINIMUM B2126 BULKHEAD Figure 6—EOL Resistor Installation (For Ex d Wiring only) Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 8...
  • Page 13 ACTIVATION SWITCH CAN BE INSTALLED AT THE FIRE PANEL. TEST SWITCHES ARE NOT SUPPLIED. 4 EOL RESISTOR SUPPLIED BY PANEL. Figure 8—Ex d e Wiring Option Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 9...
  • Page 14 INSTALLED REMOTELY OR A DETECTOR SELECTOR AND ACTIVATION SWITCH CAN BE INSTALLED AT THE FIRE PANEL. TEST SWITCHES ARE NOT SUPPLIED. Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 10...
  • Page 15 ACTIVATION SWITCH CAN BE INSTALLED AT THE FIRE PANEL. TEST SWITCHES ARE NOT SUPPLIED. Figure 14 – EEx e wiring option, AutroSafe/Autroprime Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS...
  • Page 16 ACTIVATION SWITCH CAN BE INSTALLED AT THE FIRE PANEL. TEST SWITCHES ARE NOT SUPPLIED. Figure 15 – EEx e non latching, BN-300 Figure 16 – EEx d wiring option, BS-100 Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 12...
  • Page 17: Startup Procedure

    It is highly recommended that a complete spare windows .) be kept on hand for field replacement to ensure continuous protection. Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 13...
  • Page 18: Maintenance

    . See window cleaning solution can not remove . Ordering Information for details . Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 14...
  • Page 19: Periodic Checkout Procedure

    RFI and EMC Directive compliant ASSOCIATED MANUALS List of X33AF related manuals: TITLE FORM NUMBER SIL 2 (Safety) 116-P-X33AF-SIL2/CGB 116-P-X33AFADDENDUM/YGB, HART Addendum P/N 95-8624 Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 15...
  • Page 20: Specifications

    . (11.9) 10.0 (25.4) (12.2) B2067 Figure 18—X33AF Dimensions in Inches (cm) Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 16...
  • Page 21 Mounting Arm (AL): 6 pounds (2 .75 kilograms) . Mounting Arm (SS): 14 pounds (6 .4 kilograms) . WARRANTY PERIOD— 5 years. Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 17...
  • Page 22: Accessories

    116-005003-001 1 oz grease for detectors (non-silicon) continuous protection. 116-001680-001 Window cleaner (6 pack) Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 18...
  • Page 23 *ULC approval applies to output types 11, 13, 15, 21, and 23 . **Type Approvals can use one or more letters to designate the approvals of the product . Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page 19...
  • Page 24: Report

    . This test replaces the function and need of a traditional external test lamp . Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS...
  • Page 25 1 x 1 foot 50 (15 .2) Methanol 1 x 1 foot 20 (6 .1) Methane 32 inch plume 15 (4 .6) Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page A-2...
  • Page 26 3 (0 .9) 1 x 1 foot n-Heptane 60 (18 .3) Fire was verified with very high sensitivity only . Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page A-3...
  • Page 27 Two 34 w fluorescent lamps, modulated 3 (0 .9) 1 x 1 foot n-Heptane 50 (15 .2) Outdoor test conditions . Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page A-4...
  • Page 28 1500 w electric radiant heater 3 (0 .9) No alarm No alarm Two 34 w fluorescent lamps 3 (0 .9) No alarm No alarm Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page A-5...
  • Page 29 Office Paper 0.5 lb. 19" x 19" x 8" (24 .4) Corrugated Panel 18" x 36" (24 .4) * Outdoor test condition . ** Pre-burn from ignition . Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page A-6...
  • Page 30 (degrees) Time (seconds) n-Heptane 1 x 1 foot (10.7) Methanol 1 x 1 foot (4.6) 32 inch Methane plume (4.6) Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page A-7...
  • Page 31 Field of View at Indicated Distance in Feet (m) for n-Heptane at Very High Sensitivity (6 in . x 6 in .) Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS...
  • Page 32 Methanol at Very High Sensitivity (6 in . x 6 in .) JP-5 at Very High Sensitivity (2 x 2 feet) Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page A-9...
  • Page 33 Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page A-10...
  • Page 34: Appendix B - Csa Approval

    Q9033B Stainless Steel Mounting Arm Assembly is for aluminum and stainless steel detectors 116-007290-002 Q9033A Aluminum Mounting Arm Assembly is for aluminum detectors only 116-011385-001 Q9033 Collar Attachment Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page B-1...
  • Page 35: Appendix C - Atex / Ce Approval

    The Multispectrum infrared (IR) flame detector type X33AF is to be installed in places where there is a low risk of mechanical damage . Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS...
  • Page 36 Q9033B Stainless Steel Mounting Arm Assembly is for aluminum and stainless steel detectors 116-007290-002 Q9033A Aluminum Mounting Arm Assembly is for aluminum detectors only 116-011385-001 Q9033 Collar Attachment Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page C-2...
  • Page 37: Appendix D - Iecex Approval

    Q9033B Stainless Steel Mounting Arm Assembly is for aluminum and stainless steel detectors 116-007290-002 Q9033A Aluminum Mounting Arm Assembly is for aluminum detectors only 116-011385-001 Q9033 Collar Attachment Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page D-1...
  • Page 38: Appendix E - En54 Approvals

    Q9033B Stainless Steel Mounting Arm Assembly is for aluminum and stainless steel detectors 116-007290-002 Q9033A Aluminum Mounting Arm Assembly is for aluminum detectors only 116-011385-001 Q9033 Collar Attachment Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page E-1...
  • Page 39: Appendix F - Offshore Approvals

    Q9033B Stainless Steel Mounting Arm Assembly is for aluminum and stainless steel detectors 116-007290-002 Q9033A Aluminum Mounting Arm Assembly is for aluminum detectors only 116-011385-001 Q9033 Collar Attachment Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page F-1...
  • Page 40: Appendix G - Additional Approvals

    Ex tb IIICT130°C T6 (Tamb = –55°C to +60°C) T5 (Tamb = –55°C to +75°C) T4 (Tamb = –55°C to +125°C) . Instructions, AutroFlame X33AF, 116-P-X33AF/IGB, rev . E, 2013-08-13, P/N 95-8625-17 .1, Rev: 2/13 Autronica Fire and Security AS Page G-1...
  • Page 42 www .autronicafire .com...