Fault
Insufficient
temperature
difference top/bottom
Cooling temperature
too cold
Formation of
condensation on the
door
Error message F1 on
the operation panel
Error message F2 on
the operation panel
DGS-TDS-N 05.2006 © Electrolux
Possible cause
Temperature setting
Sealing lip missing from false floor
False floor missing
Heating defect
Air flap control defective
Air flap jams
Sensors exchanged
Increased atmospheric moisture
Top sensor defect
(Appliance does not function in the
emergency programme)
Bottom sensor defect
(Appliance does not function in the
emergency programme)
Remedy
Set correctly
Fit sealing lip
Mount false floor
Inspect heating (see Diagnosis.
Replace if defect)
Inspect servomotor (see diagnosis)
Remedy air flap malfunction
Connect sensor correctly
Wipe off with a dry cloth, set a little
warmer.
Replace sensor (see 6.3.11).
Replace sensor (see 6.3.11).
7