IBR-ITAB DEALER SETTINGS MENU
IBR-ITAB Napco Security Application
This "System Settings" button can display either a partial list of
"user-only" selections or a full list of "dealer-only" selections, de-
pending on the how this button is tapped and pressed:
• User Settings: To display the partial list of "user-only" se-
lections, simply tap this button once (see OI372)
• Dealer Settings: To display the full list of "dealer-only" se-
lections, press and hold this button (password required)
When accessing the "dealer-only" selections (again, by pressing
and holding this button), a popup appears requesting a pass-
word. This password request signifies that the Dealer Settings
menu will be displayed (detailed in this section). Type the IBR-
ITAB dealer password (default is "admin") and tap OK. Tap
Yes to the warning popup that appears, and the User Settings
menu opens. Note: For descriptions of the "user-only" selec-
tions, see the User Guide for the keypad (see OI372). For Z-
Wave menu selections, see the Using your iBridge
ITAB Series Z-Wave
Home Automation System (OI378).
®
Dealer Settings > Security
Keypad Skin - Select the keypad model type configured in the
IBR-ZREMOTE. Selections include:
Classic: Displays the IBR-ITAB proprietary keypad, with
extra large keys, modeled on the Gemini "GEM-RP1CAe2"
two-line display alpha keypad, as shown in the following im-
age:
"Classic" Keypad Skin
K Series Stay / Away: Displays the IBR-ITAB proprietary
keypad with extra large keys, modeled on the Gemini
"GEM-K1CA" two-line display "K Series" Stay/Away alpha
keypad, as shown in the following image:
"K Series Stay / Away" Keypad Skin
EZ-ARM - Check to enable Easy Arming (ability to arm the
4
"System Settings" Button
alarm system quickly by simply tapping
keypad may be individually programmed for Easy Arm-
ing. Disarming still requires entry of a valid user code.
Note: Do not program Easy Arming in UL installations.
The alarm control panel must be programmed to support
this feature.
EASY EXIT - Check to enable Easy Exit. While armed in the
Interior Bypass/Stay Mode, Easy Exit can be
initiated by pressing and holding the Disarm
"pie wedge" button. Easy Exit restarts the Exit
delay (the top banner on the IBR-ITAB changes
to read "ARMING STAY...") allowing a User to
exit an armed premises without disarming and rearming
the system. Note: Do not program Easy Exit in UL in-
stallations.
grammed to support this feature.
Number of Zone Areas are - Some systems may be divided,
or partitioned, into smaller independent subsystems,
which are referred to as Areas. Tap to select the number
of Areas in the alarm system. Note: Each Area may be
controlled by its own keypad or by a keypad of a different
Area through Managers Mode (a low-security operating
mode that allows arming by area).
Connection Settings - Allows changes to be made to the net-
work communication and automatic identification settings
used between the IBR-ITAB and the ISEE-WAP. Changes
to these settings are rare; consult with the factory before
®
changing.
IBR-
Serial Interface: Indicates status if hardwired.
IP Address: Set the private TCP/IP protocol address used
for communications between the IBR-ITAB and the ISEE-
WAP.
Port No.: Set the port number used for network activities
as set by the IBR-ZREMOTE.
Autodiscovery Options: Manage the automatic recogni-
tion and connection settings between the IBR-ITAB and the
IBR-ZREMOTE.
Autodiscovery: Check to enable ongoing automatic
recognition of and connection between the IBR-ITAB
and the ISEE-WAP.
Discover: Tap to initiate the discovery (recognition of
and connection) process between the IBR-ITAB and the
IBR-ZREMOTE, setting the IP address and Port shown
on the Connection Settings screen.
Autodiscovery Port Range Base: When the IBR-ITAB
and ISEE-WAP are establishing their initial handshake
connection, the ISEE-WAP establishes four (4) listening
ports for connection. This menu item allows the starting
port number used by the ISEE-WAP to be changed from
its default setting of 8000.
Time interval to request status: Tap to enter the duration
between autodiscovery process activations.
Log Settings - Allows changes to logs (system activity used for
backup/recovery and troubleshooting).
Logging: Tap to enable log files to be created.
Logcat: Tap to enable the Logcat command, allowing the
viewing of the internal log in the Android operating system.
Helpful with diagnosing and troubleshooting system issues.
The alarm control panel must be pro-
U
D
or
). Each