6 function

Advertisement

3. SPECIFICATION

Function
DC Voltage
(V DC)
AC Voltage
(V AC)
DC Current
(A DC)
Resistance
Battery Test
NOTE! Accuracy specifications consist of two elements:
1.
(% reading) – This is the accuracy of the measurement circuit.
2.
(+ digits) – This is the accuracy of the analog to digital converter.
NOTE! Accuracy is stated at 65°F to 83°F (18°C to 28°C) and less than 75% RH.
Diode Test: ................................... Test current of 1mA maximum, open circuit voltage 2.8V DC typical.
Continuity Check: ........................ Audible signal will sound if the resistance is less than approximately 30Ω.
Battery Test Current: .................... 9V (6mA); 1.5V (100mA).
Input Impedance: ......................... >1MΩ.
ACV Bandwidth: .......................... 45Hz to 450Hz.
DCA Voltage Drop: ...................... 200mV.
Display: ........................................ 3 ½ digit, 2000 count LCD, 1.1" digits.
Overrange Indication: .................. "I" is displayed.
Polarity:........................................ Automatic (no indication for positive polarity); Minus (-) sign for negative polarity.
Measurement Rate: ..................... 2 times per second, nominal.
Low Battery Indication: ................ "BAT" is displayed if battery voltage drops below operating voltage.
Battery: ........................................ One 9 volt (PP9) battery.
Fuses: ......................................... mA, µA ranges; 0.2A / 250V fast blow.
A Range: ...................................... 10A/250V fast blow.
Operating Temperature: ............... 32°F to 122°F (0°C to 50°C).
Storage Temperature: .................. -4°F to 140°F (-20°C to 60°C).
Relative Humidity:........................ <70% operating, <80% storage.
Operating Altitude: ....................... 7000ft. (2000) meters maximum.
Weight: ....................................... 255g.
Size: .......................................... 150mm x 70mm x 48mm.
Safety: For indoor use and in accordance with Overvoltage Category II, Pollution Degree 2. Category II includes local level,
appliance, portable equipment, etc., with transient overvoltages less than Overvoltage Category III.
© Jack Sealey Limited
Range
Resolution
200mV
0.1mV
2000mV
1mV
20V
0.01V
200V
0.1V
600V
1V
200V
0.1V
600V
1V
2000µA
1µA
20mA
10µA
200mA
100µA
10A
10mA
200Ω
0.1Ω
2000Ω
1Ω
20kΩ
0.01kΩ
200kΩ
0.1kΩ
2000kΩ
1kΩ
9V
10mV
1.5V
10mV
Original Language Version
Accuracy
±(0.5% reading + 2 digits)
±(0.8% reading + 2 digits)
±(1.2% reading + 10 digits
(50/60Hz)
±(1.0% reading + 2 digits)
±(1.2% reading + 2 digits)
±(2.0% reading + 2 digits)
±(0.8% reading + 2 digits)
±(1.0% reading + 2 digits)
±(1.0% reading + 2 digits)
TM100
Issue No:2(I) - 18/06/14