3. speciFication

Dc voltage (Auto Ranging)
range
resolution
400.0mV
0.1mV
4.000V
1mV
40.00V
10mV
400.0V
100mV
1000V
1V
Input Impedance: 10MΩ.
Maximum Input 700Vac rms or 1000Vdc.
ac voltage (Auto Ranging except 400mV)
range
resolution
400.0mV
0.1mV
4.000V
1mV
40.00V
10mV
400.0V
100mV
700V
1V
Input Impedance: 10MΩ.
Frequency Range: 50 to 400Hz.
Maximum Input: 700Vac rms or 100Vdc.
capacitance (Auto Ranging)
range
resolution
40.00nF
10pF
400.0nF
0.1nF
4.000uF
1nF
40.00uF
10nF
100.0uF
0.1uF
Input Protection: 250Vac rms or 250Vdc.
Resistance (Auto Ranging)
range
resolution
400.0Ω
0.1Ω
4.000kΩ
1Ω
40.00kΩ
10Ω
400.0kΩ
100Ω
4.000MΩ
1kΩ
40.00MΩ
10kΩ
Input Protection: 250Vac rms or 250Vdc.
Diode test
range
resolution
0.3mA
1mV
typical
open Circuit Voltage: 1.5Vdc typical
overload Protection: 250Vac rms or dc.
temperature
range
resolution
-20°C~+760°C 1°C
-4°F~+1400°F
1°F
Sensor: Type K Thermocouple
RPM (Tach)
range
resolution accuracy
RPM 4 600~4000RPM
1RPM
600~1200RPM
10RPM
(X 10PM)
RPM 2 300~4000 RPM
1RPM
300~600RPM
10RPM
(x 10RPM)
effect Reading: >600RPM
overvoltage Category: ..................................................................................................................... CAT11 1000V.
display: ......................................................................................4000 counts lCd display with function indication.
Polarity: .................................................................................................Automatic, (-) negative polarity indication.
overrange: ............................................................................................................................."ol" mark indication.
low Battery Indication: ............The "BAT" is displayed when the battery voltage drops below the operating level.
Measurement Rate: .....................................................................................................2 times per second nominal
Auto Power off: .......................................... Meter automatically shuts down after approx 30 minutes of inactivity.
operating environment: ...................................................... 0°C to 50°C (32° to 122°F) at < 70%relative humidity.
Storage Temperature: ....................................................... -20° to 60°C (-4°F to 140°F) at <80% relative humidity.
For Inside Use:
Max Working Height: ................................................................................................................................2000mtr.
Power: ....................................................................................................................................one 9V battery PP3.
dimensions: ...............................................................................................................195 (H) x 92 (W) x36 (d) mm
Approx Weight: ................................................................................................................................................360g
accuracy is given at 18°c to 28°c (65°F to 83°F) less than 70% relative humidity.
© Jack Sealey limited
accuracy
± 0.5% of reading ± 2 digits
±1.5% of reading ± 2 digits
± 1.8% of reading ± 2 digits
accuracy
± 1.5% of reading ± 30 digits
± 1.0% of reading ± 3 digits
± 1.5% of reading ± 3 digits
± 2.0% of reading ± 2 digits
accuracy
± 5.0% of reading ± 7 digits
± 3.0% of reading ± 5 digits
± 5.0% of reading ± 5 digits
accuracy
± 1.2% of reading ± 4 digits
± 1.0% of reading ± 2 digits
± 1.2% of reading ± 2 digits
± 2.0% of reading ± 3 digits
accuracy
± 10% of reading ±5 digits
accuracy
± 3.0% of reading ± 3 digits
(Meter only, probe accuracy
not included).
±2% of rdg ± 4 digits
Original Language Version
Duty cycle (Auto Ranging)
range
resolution
0.1%~99.9%
0.1%
Pulse Width: >100us, <100ms
Frequency Width: 5Hz - 150kHz
overload Protection: 250Vac rms or dc.
pulse Width
range
resolution
1.0~10.0ms
0.1ms
overload Protection: 250Vac rms or dc.
Dwell angle
cylinder range
resolution
4CYl
0~90.0°
0.1°
5CYl
0~72.0°
6CYl
0~60.0°
8CYl
0~45.0°
overload Protection: 250Vac rms or dc.
Frequency (Auto Ranging)
range
resolution
5Hz
0.001Hz
50Hz
0.01Hz
500Hz
0.1Hz
5kHz
1Hz
50kHz
10Hz
500kHz
100Hz
10MHz
1kHz
Sensitivity: <0.5V RMS while <1MHz
Sensitivity: >3V rms while >1MHz
overload Protection: 250Vac rms or dc.
Dc current (Auto Ranging for uA and mA)
range
resolution
400.0uA
0.1uA
4000uA
1uA
40.00mA
10uA
400.0mA
100uA
4A
1mA
20A
10mA
overload Protection: 0.5A/250V and 20A/250V
Fuse:
Maximum Input:400mAac rms or 400mAdc on uA/mA ranges
20A ac or dc rms on 10A range.
ac current (Auto Ranging for uA and mA)
range
resolution
400.0uA
0.1uA
4000uA
1uA
40.00mA
10uA
400.0mA
100uA
4A
1mA
20A
10mA
overload Protection: 0.5A/250V and 20A/250V
Fuse:
Frequency Range:50 to 400Hz
Maximum Input: 40mA ac rms or 400mA dc on uA/m7
20A ac or dc rms on 20A range.
audible continuity
Audible threshold:
less than 150Ω
Test Current:
<0.3mA
overload Protection:
250Vac rms or dc.
TA202 Issue 5 (-6) 20/09/18
accuracy
± 1.2% of reading ± 2 digits
accuracy
± 3% of reading ± 10 digits
accuracy
± 2.0% of reading ± 4 digits
accuracy
± 1.5% of reading ± 5 digits
3
± 1.2% of reading ±
digits
± 1.5% of reading ± 4 digits
accuracy
± 1.0% of reading ± 3 digits
± 1.5% of reading ± 3 digits
± 2.5% of reading ± 5 digits
accuracy
± 1.5% of reading ± 5 digits
± 3.0% of reading ± 7 digits