WARNING! NEVER apply voltage or current to the meter that exceeds the specified maximum as shown below:

Input Limits

Function
V AC
600V DC/AC, 200Vrms on 200mV
V DC or V AC
mA DC
200mA 250V fast acting fuse
10A 250V fast acting fuse
A DC
(30 seconds max every 15 minutes)
Resistance,
Continuity
WARNING! USE EXTREME CAUTION when working with
high voltages.
1.4.

BATTERY INSTALLATION

WARNING! To avoid electric shock, disconnect the test
leads from any source of voltage before removing the battery
cover.
Disconnect the test leads from the meter.
Open the battery cover by loosening the two cover screws
using a Phillips head screwdriver.
Insert the battery into battery holder, observing the correct
polarity.
Replace the battery cover. Secure with the screws.
WARNING! To avoid electric shock, do not operate the meter
until the battery cover is in place and fastened securely.
NOTE! If your meter does not work properly, check the fuses and
battery to make sure that they are still good and that they are
properly inserted.
2. FEATURES
High precision multimeter. Conforms with EN61010-1 CATIII
600V safety requirements for electrical equipment for
measurement, control, and laboratory use. Double moulded
housing with soft grip case and large display for ease of use.
Probe and lead storage and integral upright stand for use on the
workbench. Supplied in zipped pouch with carry strap.
Measures:
• AC and DC Voltage
• DC Current
• Resistance
• Diode Test
• Continuity Buzzer
1.
LCD Display
2.
Function Switch
3.
10A Jack
4.
COM Jack
5.
Positive Jack
6.
Note: Tilt stand, fuse and battery
compartment are on rear of unit.
SYMBOLS AND ANNUNCIATORS
•)))
Continuity
Diode Test
µ
Micro (amps)
m
Milli ( volts, amps)
k
Kilo (ohms)
Ohms
VDC
Volts Direct Current
VAC
Volts Alternating Current
ADC
Amps Direct Current
BAT
Battery Test
© Jack Sealey Limited
Maximum Input
600V DC/AC
range
250Vrms for 15sec max
Original Language Version
REMOVE SCREWS
1
2
3
TO ACCESS
BATTERY AND
FUSES
4
TM100
Issue No:2(I) - 18/06/14