Download Print this page

Specification - Sealey MM104 Instructions Manual

Professional auto-ranging digital multimeter

Advertisement

4. sPeCifiCation

model no .................................................................... mm104
function
dc Voltage
Ac Voltage
All AC voltage ranges are specified from 5% of range to 100% of range
dc current
Ac current
resistance
capacitance
frequency
(electrical)
duty cycle
note: Accuracy is stated at 18°c to 28°c and less than 75% rH
Note: Accuracy specifications consist of two elements:
a) (% reading) - this is the accuracy of the measurement circuit.
b) (+ digits) - this is the accuracy of the analog to digital converter.
enclosure...........................................................double molded
shock (drop test).............................................. 6.5 feet (2 meters)
transistor test.....................................................no
diode test..........................................................Yes
continuity Check................................................Audible signal will sound if the resistance is less than 50Ω (approx.), test current <0.35mA
temperature sensor...........................................requires type K thermocouple
input Impedance.................................................>10MΩ VDC & >10MΩ VAC
Ac response.....................................................trms
AcV Bandwidth..............................................50/60HZ(All WAVe) 45Hz to 1000Hz(sine WAVe)
© Jack sealey limited
rAnGe
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400µA
4000µA
40mA
400mA
4A
10A
(20A: 30 sec max with reduced accuracy)
400µA
4000µA
40mA
400mA
4A
10A
(20A: 30 sec max with reduced accuracy)
400Ω
4KΩ
40KΩ
400KΩ
4MΩ
40MΩ
40nf
400nf
4µf
40µf
400µf
4000µf
10KHz
99.9%
Original Language Version
AccurAcY
±(1.0%reading+5digits)
± (1.0%reading+3digits)
50Hz to 60Hz
± (1.2%reading+3digits)
± (1.0%reading+3digits)
± (1.2%reading+3digits)
50Hz to 60Hz
± (1.2%reading+3digits)
± (1.8%reading+5digits)
± (1.5%reading+5digits)
± (2.5%reading+20digits)
± (4.5%reading+10digits)
± (3.0%reading+5digits)
± (5%reading+5digits)
± (1.5%)
± (1.2%)
mm104 | issue 1 13/09/16

Advertisement