Software Upgrade; Flexing; Testing On Hp8922 - Motorola M3588 Service Manual

Hide thumbs Also See for M3588:
Table of Contents

Advertisement

M3588
9. Internal Charger not working
10. No / Weak audio when using
headset
6.5

Software Upgrade

For information on setting up and equipment required for the flashing of software, contact should be
made with the local technical support engineer.
6.6

Flexing

For information on setting up and equipment for flexing, contact should be made with the local
technical support engineer.
6.7

Testing on HP8922

HP8922
GSM Test
Set
27
of 45
c) Logic/RF Board Assembly
Defective.
a) Faulty charger circuit on main
Board.
a) Headset not fully pushed
home
b) Faulty Jack Socket /
Defective PCB
European Customer Services
good one. Reassemble unit. Place call to portable
phone and verify ability to answer by opening flip. If
fault still present, replace original reed switch and
proceed to c.
Replace Logic/RF Board Assembly (refer to
symptom 1c). Verify that the
Fault has been cleared and re-assembles the unit with
the new PCB.
Test a selection of batteries in the rear pocket of the
desktop charger.
Check LED display for the charging indications. If
these are charging ok,
then the internal charger is at fault.
Replace Logic/RF Board Assembly (refer to
symptom 1c). Verify that the
Fault has been cleared and re-assembles the unit with
the new PCB.
Fully ensure the ' click' is felt on the jack socket.
Replace Logic/RF Board Assembly (refer to
symptom 1c). Verify that the
fault has been cleared and re-assemble the unit with
the new PCB.
Power Supply

Advertisement

Table of Contents
loading

Table of Contents