Replacing An Existing Drain Pump - AGA marvel 3OiMT Installation, Operation And Maintenance Instructions

Sealed reservoir drain pump 41013943 115vac/60hz
Table of Contents

Advertisement

Available languages

Available languages

Replacing an existing drain pump:

1. Remove the ice machine from the installation and un-
plug the power cord from the electrical outlet.
2. Remove the 2 screws from the vent tube clamps and
all of the screws around the perimeter of the access
cover with the
" nutdriver. remove the access cover
5
16
from the ice machine. (See Figure 9).
3. Remove the 3 hose clamps from the drain pump and
remove the 3 tubes from the drain pump. See Figure
10.
4. Remove the leveling leg in the left back corner. See
Figure 10.
NOTE
Inspect the following parts for damage, 18" (45.7 cm)
vent tube, 20 feet (6.1 meters) discharge tube, and hose
clamps. Replacement parts, if required, are provided in the
drain pump kit.
Remove these 3 hose
clamps, then remove
the 3 tubes from the
drain pump
Remove this rear leveling leg
DRAIN PUMP INSTALLATION
Remove screws
around perimeter
Drain pump ground
Figure 10
wire connection
8
Vent tube
Remove (2)
screws from
vent tube
clamps
of access cover
Figure 9
Dis-
charge
line
Access
cover
Electrical
power cord