Electrolux AOS061E Series Service Manual page 33

Hide thumbs Also See for AOS061E Series:
Table of Contents

Advertisement

Electrolux Professional S.p.A.
Ovens Platform Customer Support
Technical Training & Service
LPG conversion for cavity burner for AOS101G
For LPG installations, put the ø 21 flow reducer flange between cavity burner fan and cavity burner. Change
the PWM parameters.
Then change the injector with the 5.70 one and calibrate the offset in the range - 0.15 ÷ - 0.08 hPa so as to
eliminate possible whistles/noises (row LPG1). After you have found the best working condition, cool down
and verify ignitions with cold burner.
If the previous setting does not eliminate whistles or noise, change the 5.70 injector with the 5.50 one and
use the calibrations of LPG2/G30 row: calibrate the offset in the range - 0.07 ÷ 0.00 hPa so as to eliminate
possible whistles/noises (row LPG1). After you have found the best working condition, cool down and verify
ignitions with cold burner.
File: AOS service manual (ENG).008
AOS101G
CAVITY BURNER
GAS
Injector
Aerator
G20
7.00
Red
G25
8.00
Red
LPG2/30
5.50
Red
LPG1
5.70
Red
BOILER BURNER
GAS
Injector
Aerator
G20
7.00
Red
G25
8.00
Red
G30
5.70
Red
LPG
5.70
Red
©Copyright 2002 by Electrolux Professional
AOS OVENS - Service Manual
(595889300 – ENG)
OFFSET
Parameters
(hPa)
StcA hAcA FucA
- 0.25
80
26
- 0.25
80
26
- 0.07÷ 0.00
23
26
- 0.15÷ - 0.08 23
26
Parameters
OFFSET
(hPa)
Stbo hAbo Fubo
- 0.10
50
50
- 0.10
40
50
- 0.28
33
45
- 0.15
33
45
100
100
100
100
100
100
74
74
P.33/40