Change Of The Microprocessor Board - Electrolux AOS061E Series Service Manual

Hide thumbs Also See for AOS061E Series:
Table of Contents

Advertisement

Electrolux Professional S.p.A.
Ovens Platform Customer Support
Technical Training & Service
Using the pressure inlet signed with "–" and with negative reading on the display as in the fig.31-32, this
means we are measuring + 0.16 hPa = + 16 Pa:
Fig. 31
Using the pressure inlet signed with "
means we are measuring – 0.16 hPa = – 16 Pa:
Fig. 33

14. Change of the microprocessor board

In case of changing of the microprocessor board, the following operations/calibrations have to be done:
1) Default parameter programming
2) Change parameters according parameter list
3) Lambda probe calibration for lev. A ovens (from firmware 2.6)
4) By-pass calibration (lev. B ovens) and cavity offset (parameter OCA1) or only cavity offset for lev. A
ovens.
File: AOS service manual (ENG).008
AOS OVENS - Service Manual
(595889300 – ENG)
" and with positive reading on the display as in the fig. 33-34, this
©Copyright 2002 by Electrolux Professional
Fig. 32
Fig. 34
P.18/40