Appendix F - Parameter Descriptions - Electrolux AOS061E Series Service Manual

Hide thumbs Also See for AOS061E Series:
Table of Contents

Advertisement

Electrolux Professional S.p.A.
Ovens Platform Customer Support
Technical Training & Service
APPENDIX F – PARAMETER DESCRIPTIONS
Name
5060
Frequency
6Prb
Presence of 6-point meat probe (1=yes for lev. A, 0 for lev. B)
AbSP
Flag to enable starting of cooking closing the door (0=disable; 1=enable)
Addr
RS485 address
ALFn
Activation of cavity motor thermal protection
APPL
Level of the oven
APPM
Type of oven
bAud
RS485 bit rate
bot
Max. steam generator overheating (ETUB alarm)
CLPr
Length of cooling with humidifier after a steam phase in an automatic cleaning cycle
CLt1
Length of detergent injection (phase A)
CLt2
Length of detergent+water injection (phase A)
CLt3
Length of rinser+water injection (phase C)
CLt4
Length of water injection (phase C)
cort
Flag to enable cavity temperature displaying adjustment
cot
Max. cooking chamber overheating (ETUC alarm)
cu
Parameter q of SCELOFF=SCEL-(q+m*dT/dt) (FUZZY-LOGIC)
dbon
Delay for boiler drain
dCLn
Flag to disable automatic cleaning cycles (1=disable)
dEMO
Flag to enable DEMO (0=disable; 1=enable)
Temperature range (from set) above which the middle power is activated in combi
dScb
mode
Flag to disable the oven stops when door is open in convection, steam and combi
dSod
mode: (0=the oven stops)
Flag to disable pre-heating of the boiler when the oven is in stand-by mode (0=enable
dSPS
pre-heating; 1=disable)
Max. cooking chamber temperature derivative value for heating elements to be
dtoF
switched OFF (FUZZY-LOGIC)
Max. cooking chamber temperature derivative value for heating elements to be
dton
switched ON (FUZZY-LOGIC)
dtSb
Delay for activation of fast filling during opening of boiler drain valve
dutM
Maximum length of a phase with cavity temperature over 250 ºC
EMME
Parameter m of SCELOFF=SCEL-(q+m*dT/dt) (FUZZY-LOGIC)
EnFL
Presence of motorised cavity flap (1=yes)
Ertc
Flag to enable RTC (1=enable)
FAHr
Temperature unit (°F = 1, °C = 0)
FrE
PWM frequency
Fubo
PWM value at full power of boiler burners
FucA
PWM value at full power of cavity burners
GAS
Define if the oven is GAS heated (1) or ELECTRIC heated (0)
hAbo
PWM value at middle power of boiler burners
HAbP
Steam condenser engagement in "hot air" mode
hAcA
PWM value at middle power of cavity burners
HAFd
Bypass temperature variation for humidification during hot air mode + open flap
HAFI
By pass isteresys in hot air+open flap mode
HAFS
Bypass base temperature for humidification during hot air mode + open flap
hAir
Hot air hour counter
File: AOS service manual (ENG).008
AOS OVENS - Service Manual
(595889300 – ENG)
Description
©Copyright 2002 by Electrolux Professional
P.30/40

Hide quick links:

Advertisement

Table of Contents
loading