Frozen Water Pipe Hazard

CAUTION
!
WATER DAMAGE TO PROPERTY HAZARD.
Failure to follow this caution may result in property
damage.
Do not leave your home unattended for long periods
during freezing weather without turning off water
supply and draining water pipes or otherwise
protecting against the risk of frozen pipes and
resultant damage.
Your furnace is designed solely to provide a safe and comfortable
living environment. The furnace is NOT designed to ensure that
water pipes will not freeze. It is equipped with several safety
devices that are designed to turn the furnace off and prevent it from
restarting in the event of various potentially unsafe conditions.
If your furnace remains off for an extended time, the pipes in your
home could freeze and burst, resulting in serious water damage.
If the structure will be unattended during cold weather you should
take these precautions.
1.
Turn off the water supply to the structure and drain the water
lines if possible and add an antifreeze for potable water to
drain traps and toilet tanks. Open faucets in appropriate
areas.

2. Installation

WARNING
!
CARBON MONOXIDE POISONING HAZARD.
Failure to follow this warning could result in
personal injury or death.
This furnace can NOT be common vented or
connected to any type B, BW or L vent or vent
connector, nor to any portion of a factory- -built or
masonry chimney. If this furnace is replacing a
previously common-vented furnace, it may be
necessary to resize the existing vent and chimney to
prevent oversizing problems for the other
remaining appliance(s). See Venting and Combus-
tion Air Check in Gas Vent Installation section. This
furnace MUST be vented to the outside.

Location and Clearances

1.
Refer to Figure 1 or Figure 2 for typical installation and
basic connecting parts required. Refer to Figure 5 for
typical horizontal direct vent installation and basic
connecting parts required. Supply and return air plenums
and duct are also required.
2.
If furnace is a replacement, it is usually best to install the
furnace where the old one was. Choose the location or
evaluate the existing location based upon the minimum
clearance and furnace dimensions (Figure 3).
440 01 1024 01
--or--
Specifications are subject to change without notice
2.
Have someone check the structure frequently during cold
weather to make sure it is warm enough to prevent pipes
from freezing. Instruct them on a service agency to call to
provide service, if required.
3.
Install a reliable remote sensing device that will notify
somebody of freezing conditions within the home.

Winter Shutdown

If you go away during the winter months and do not leave the heat
on in your home, the plastic transition box and the condensate trap
on the furnace must be protected from freeze damage.(See
Figure 11 trough Figure 20)
5
1.
Disconnect the
/
" OD rubber hose from the vent drain
8
fitting that is located downstream of the combustion blower.
Insert a funnel into the hose and pour four(4) ounces of
sanitary type (RV) antifreeze into the condensate trap.
5
Reconnect the
/
" OD rubber hose to the stub on the vent
8
drain fitting. Secure with the hose clamp.
3
2.
Disconnect the
/
" OD rubber hose from the condensate
4
trap. Insert a funnel into the hose and and pour four(4)
ounces of sanitary type (RV) antifreeze into the plastic
Transition box. Squeeze the hose together near the end and
3
quickly reconnect the
condensate trap. Secure with the hose clamp.
When you return home, your furnace will be ready to start, as it is
not necessary to drain the antifreeze from the furnace.
Figure 1
Typical Upflow Installation
Aluminum or non- rusting shield recommended. (See
Vent Termination Shielding for dimensions).
*8" Min.
20' Max.
in same
atmospheric
zone
Vent Pipes MUST be
supported Horizontally
and Vertically
*
Increase minimum from 8" to 18" for cold climates (sustained temperatures
0°F(--18°C) and below for 24 or more consecutive hours).
--or--
/
" OD rubber hose to the stub on the
4
Coupling on ends of
exhaust pipe. Total
Inlet Pipe (not
pipe & coupling out-
used on Single
side structure = 8"
Pipe model)
*8" Min.
20' Max. in same
atmospheric
zone