Gas Supply And Piping; Concentric Vent Sidewall Attachment; Gas Pressures; Gas Supply Requirements - Arcoaire N9MP1 Installation Instruction

90+ single stage gas furnace direct or non--direct vent fan assisted category iv furnace
Table of Contents

Advertisement

Concentric Vent and Combustion- -
Figure 35
Air Side Termination
1" max.
Combustion
Air
Vent

6. Gas Supply and Piping

WARNING

!
FIRE AND EXPLOSION HAZARD.
Failure to follow this warning could result in
personal injury, death and/or property damage.
Models designated for Natural Gas are to be used
with Natural Gas ONLY, unless properly converted to
use with Propane gas.
NOTE: The rating plate is stamped with the model number, gas
type and gas input rating. In addition, models manufactured for
sale in Canada have orifice size information stamped on the rating
plate.

Gas Supply Requirements

Gas supply pressure should be within minimum and maximum
values listed on rating plate. Pressures are usually set by gas
suppliers.
(See Propane Gas Conversion Kit instruction manual for furnaces
converted to Propane gas)
Use only the Type of gas approved for this furnace. See
rating plate for approved gas type.
1
A
/
" NPT plugged tapping, accessible for a test gauge
8
connection,must be installed immediately upstream of the
gas supply connection to furnace.
Gas supply pressure should be within minimum and
maximum values listed on rating plate. Pressures are
usually set by gas suppliers.
Gas input must not exceed the rated input shown on the
rating plate. Overfiring will result in failure of heat exchanger
and cause dangerous operation.
Do NOT allow minimum gas supply pressure to vary
downward. Doing so will decrease input to furnace. Refer to
Table 8, Table 9, Table 10, Table 11 and Table 12 for
normal gas supply and manifold pressures.
440 01 1024 01
Roof Overhang
12" min.
Maintain 12" clearance above highest antici-
pated snow level or grade whichever is greater.
25--22--02
Specifications are subject to change without notice
Concentric Vent Sidewall
Figure 36
Attachment
Vent
Combustion
Air
45° Elbow
(Field Supplied)
Note:
Securing strap must be field installed to prevent movement of termination kit in side wall.
Table 7

Gas Pressures

Gas Type
Recommended
Natural
7"
Propane
11"
Gas Piping Requirements
NOTE: The gas supply line must be installed by a qualified service
technician in accordance with all building codes.
NOTE: In the state of Massachusetts.
a.
Gas supply connections MUST be performed by a
licensed plumber or gas fitter.
b.
When flexible connectors are used, the maximum length
shall not exceed 36".
c.
When lever handle type manual equipment shutoff
valves are used, they shall be T--handle valves.
d.
The use of copper tubing for gas piping is NOT approved
by the state of Massachusetts.
1.
Install gas piping in accordance with local codes, or in the
absence of local codes, the applicable national codes. Refer
to NFGC and ANSI Z223.1 for proper gas pipe size.
2.
It is recommended that a manual equipment shutoff valve be
installed in the gas supply line outside the furnace. Locate
valve as close to the furnace as possible where it is readily
accessible. Refer to Figure 37.
3.
Use black iron or steel pipe and fittings or other pipe approved
by local code.
4.
Use pipe thread compound which is resistant to natural and
Propane gases.
5.
Use ground joint unions and install a drip leg no less than 3"
long to trap dirt and moisture before it can enter gas control
valve inside furnace.
NOTE: Refer to Figure 37 or Figure 38 for the general layout at
the furnace. The rules listed apply to natural and Propane gas pipe
installations.
NOTE: On the Dual Certified or Direct Vent models, install the gas
pipe grommet to the furnace side panel with the gas pipe entry. If
needed, remove the 2" hole plug from the plastic accessory bag
and relocate to the open hole in the furnace side panel.
Strap
Combustion
(Field Supplied)
Air
Vent
Flush to
1" max.
25--22--02
Supply Pressure
Max.
Min.
14"
4.5"
14"
11"
33