Introduction

The clock thermostat type WLCT is part of the underfloor heating system type WLM. The thermostat can be set to control one single room, or it can be set
as a master to control a group of thermostats / rooms/zones.
All the thermostats that are part of that group will follow the times and temperatures programmed into the clock thermostat. For example, if the temperature
programmed in the clock thermostat is 22°C, all the thermostats / rooms belonging to that group will then also be controlled at 22°C. Depending on the
types of thermostats used you can adjust the temperature + or -4°C in different rooms, giving a possible room setpoint of +18 to +26°C.
The clock thermostat can be programmed to work at different temperatures during the day allowing lower temperatures during times that the room is
unoccupied. Lower temperatures will lower your energy costs without reducing the comfort. All thermostats that are part of the group will follow any new
time or temperatures programmed in the clock thermostat.
When it leaves the factory, the thermostat has a preset program suitable for most installations.
You only need to set the clock and day, and define the thermostats / rooms that should belong to the group.
The thermostat has a pin button marked R (see fig. 1), allowing you, at any time, to reset the thermostat to the factory settings. These are listed at the end of
this manual with space for you to record your own weekly schedule.

1. Getting started

Fig. 1 - Buttons
A:
B:
C:
Display
Adjustment
OK -
down
accept
D:
E:
F:
Adjustment
Reset to
Pin button
up
factory
adjust of
setting
clock

Setting the thermostat into operation

First time power is connected the clock and day will be flashing and must be set. If you need to
adjust the time of the thermostat at a later date, insert a pin into the hole marked
for setting of time and day. Adjustment should be made for change in summer and winter time.
Press the UP (
the correct hours and press OK button (
Press the UP (
the correct minutes and press OK button (
Then press the UP (
select the correct day and press OK (
Type: WLCT

Display symbols

G:
Automatic
mode
J:
Day number
) or DOWN (
) buttons to select
).
) or DOWN (
) buttons to select
).
) or DOWN (
) button to
) button.
G
K
H
J
I
H:
I:
Manual
Time and
mode
temperature
K:
4-event symbol
Wake
Out
Night
Home
(see fig. 1)
1-7

Advertisement

loading

Summary of Contents for OJ Electronics WLCT

  • Page 1 Introduction The clock thermostat type WLCT is part of the underfloor heating system type WLM. The thermostat can be set to control one single room, or it can be set as a master to control a group of thermostats / rooms/zones.
  • Page 2 2. Daily use of the thermostat 4-event clock mode The day has been split into 4 events describing a typical day. When the thermostat is in this 4-event mode it will change the temperature to the required level automatically at the programmed times. As standard the thermostat has 5 days with 4 events (two ON’s and two OFF’s), and 2 days with 2 events (one ON and one OFF).
  • Page 3 The limit temperatures defined in the clock thermostat will be valid for all the thermostats with limit sensor (type WLTD-19) which are part of the group of thermostats allocated to the WLCT unit. ☞ The maximum allowable floor temperature setting is shown. Use...
  • Page 4 ArEA - Zone The thermostats / rooms that are to be set as part of the WLCT group will follow the temperature settings of the clock thermostat. For example, a group could be the living room kitchen, and children’s rooms having a high room temperature during afternoon and early evening, and a lower temperature during the early part of the day and at night.