Hide thumbs Also See for CU1526:
Table of Contents

Advertisement

CU1526, CU2026, CU3030
Service Manual

Restarts

Power Interruption
The controller will automatically restart the ice machine after adequate voltage has been restored. This
also occurs after the on-off switch has been cycled.
H blinks on code display
Status indicator light blinks
Reservoir is drained and refilled
Default harvest is initiated. The curtain switch does not have to open to terminate harvest, harvest will
continue until the default harvest time expires. Default harvest time is 3 minutes. The machine will then
return to a normal freeze cycle.
Water Interruption
Water must fill the reservoir within the pre-set time period. If it does not, the controller will all ice
making to proceed. The water and status lights will blink and code 3 will be displayed. Controller
will automatically check for water every 20 minutes and restart when the reservoir is full.
May 2008
Page 25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu2026Cu3030

Table of Contents