Key Functions in Panel Test Mode and
Panel Tune Mode
Knob/Key
Test mode
Test mode/Tune mode changeover
SCN
NB ON/OFF
MON
Frequency CH down
A
Frequency CH up
B
Signalling CH down
C
Signalling CH up
■ Function panel
Volume
control
LCD
MON
A
B
Power
A key
switch
MIC
MON key
B key
connector
Panel Test Mode
The transceiver's transmission output, receive sensitiv-
ity, and other items are measured and QT, DQT, 2-tone and
DTMF signaling is decoded in this mode.
■ To enter the panel test mode
Hold down [MON] and turn the power switch on to enter
this mode. The test frequency channel and test signalling
channel will be displayed.
NB on
Test frequency CH
Note : When a key other than GRP down is pressed, the
optional signalling is reset.
ADJUSTMENT
Tune mode
Monitor ON/OFF
Tuning value back up
Tuning item down
Tuning item up
Tuning value down
Tuning value up
DW key
UP key
C
SCN
C key
TX/BUSY
LED
SCN key
Test signalling CH
■ Test frequency channel (MHz) : Default setting
K
CH
TX
1 (Center)
33.300
2 (Low)
29.700
3 (High)
37.000
4
33.300
5
33.500
6
33.700
■ Test signalling channel : Default setting
CH No.
Encode tone
1
None
2
100Hz square wave
3
QT 67.0Hz
4
QT 151.4Hz
5
QT 210.7Hz
6
DQT 023N
7
Single tone 1633Hz
8
DTMF [9]
9
MSK
Panel Tune Mode
The transceiver is adjusted in this mode.
■ To enter the panel tune mode
Press the [
] key in the panel test mode.
The adjustment items, the frequency and signalling,
other than the maximum deviation and sensitivity, return to
the values that were effective for the test frequency chan-
nel and test signalling channel before entering the panel
tune mode.
TK-6110
K2
RX
TX
RX
33.400
42.500
42.600
29.800
35.000
35.100
36.900
50.000
49.900
33.300
42.500
42.500
33.500
42.700
42.700
33.700
42.900
42.900
Decode tone
None
None
QT 67.0Hz
QT 151.4Hz
QT 210.7Hz
DQT 023N
2-tone 321.7/928.1Hz
DTMF [159]
None
15