2 AI-01 Module

2.3.3 Self Configuration

2.3.3 Self Configuration

The MP2300, MP2200, and MP2100M machine controllers in the MP2000-series have a self configuration function.
With self configuration, the I/O leading and end registers for the AI-01 Module will be automatically allocated and all
of the channels will be shown as being unused if (no channel has been selected in the AI-01 Configuration window).
32
8 words (fixed) are allocated start-
ing from the register number that
can be used.
All channels are in unused status.