Technical Specifications - Velleman DVM630 User Manual

Multimeter with usb + lan cable tester
Table of Contents

Advertisement

Available languages

Available languages

1.
Switch off the meter.
2.
Remove the test probes from the circuit under test. Remove the test
leads from the input sockets.
3.
Remove the protective cover, and remove the batteries.
4.
Unscrew the screws at the back of the meter and gently open the
housing.
5.
Replace the blown fuse with a fuse of the same type and rating.
6.
Close the housing and tighten the screws.
7.
Place the battery back and close the battery cover.
8.
Put the protective cover back.
Storage
Remove the batteries from the device if it will not be used for a long time.
Old batteries can begin to leak and damage the device.
Do not store the device in a high temperature or high humidity
environment.

9. Technical Specifications

overvoltage/installation
category
pollution degree
altitude
operating temperature
and humidity
storage temperature
max. voltage between
probe and ground
test leads specification 10A/600V
fuse protection
display
maximum display
LCD display size
ranging mode
over range indication
low battery indication
polarity indication
data hold
automatic power-off
V. 01 – 22/04/2013
DVM630
CAT II 600V
class 2
< 6500 ft
32 °F - 104 °F
< 75 % RH
14 °F - 140 °F, remove battery
600 VDC or VAC
fuse 1: 200mA/600V
fuse 2: 10A/600V
mA terminal fuse: 200mA/600V (resettable)
10A terminal fuse: Ø 0.197" x 0.787"
(Ø 5 x 20 mm) 10A/600V (fast)
3½ digit LCD with automatic indication of functions
and symbols
1999
1.8" x 0.7"
manual
yes, "1"
yes,
"–" displayed automatically
yes
no
16
©Velleman Inc.