6. Technical Specifications

Accuracy is specified for one year after calibration at operating temperatures of 18°C ~ 28°C (64°F ~ 82°F) with a relative humidity at
0% ~ 75%. Accuracy specifications take the form of ± (% of rdg + number of least significant digits).
Environmental Conditions
Pollution Degree
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Max. Voltage between Terminals and Earth
Fuse Protection
Sample Rate
Display
Over Range Indication
Low Battery Indication
Polarity Indication
Data Hold
Backlight
Auto Power-Off
Power Supply
Dimensions
Weight
Accessories
No-Contact AC Voltage Detector
Sensitivity
> 50V
DC Voltage
Range
400mV
4V
40V
400V
1,000V
Input impedance: 10MΩ
Max. input voltage: 1000VDC or 750VAC RMS
AC Voltage
Range
4V
40V
400V
750V
Input impedance: 10MΩ
Max. input voltage: 1,000VDC or 750VAC RMS
Frequency range: 40Hz ~ 400Hz
Response: avg, calibrated in RMS of sine wave
DC Current
Range
4,000µA
400µA
10A
Overload protection: F500mA/250V fuse for µA and mA ranges
Max. input current: 400mA DC or 400mA AC RMS for µA and mA ranges, 10A DC or 10A AC RMS for 10A ranges
DVM1500
1,000V CAT. II and 600V CAT. III
2
< 2,000m
0°C~40°C or 32°F~122°F (< 80% RH, < 10°C)
-10°C~60°C or 14°F~140°F (< 70% RH, battery removed)
0.1x / C° (< 18°C or > 28°C)
750VAC RMS or 1,000VDC
µA and mA, F500mA / 250V, 5 x 20mm
3x/sec for digital data
3
digits LCD with automatic indication of functions and symbols
¾
yes ("OL")
yes (
)
"-" displayed automatically
yes
yes
yes
3 x 1.5V AAA batteries
156 x 82 x 29mm
± 220g (with batteries)
manual, test leads, batteries, K-type thermocouple
Frequency
50Hz
Resolution
0.1mV
1mV
10mV
100mV
1V
Resolution
1mV
10mV
100mV
1V
Resolution
1µA
0.1mA
10mA
7
Distance
< 150mm
Accuracy
± (0.8% of rdg + 3 digits)
± (0.8% of rdg + 3 digits)
± (1.0% of rdg + 3 digits)
Accuracy
± (1.0% of rdg + 3 digits)
± (1.2% of rdg + 3 digits)
Accuracy
± (1.2% of rdg + 3 digits)
± (2.0% of rdg + 8 digits)