ABB REC603 Product Manual page 18

Wireless controller
Table of Contents

Advertisement

Wireless Controller
REC601/603
Product version: 1.0
Table 9. Electromagnetic compatibility tests
Description
Electrostatic discharge test:
• Contact discharge:
• Indirect contact discharge:
Conducted RF Immunity test:
• 150 kHz...80 MHz
Radiated RF Immunity test:
• 80...2700 MHz
Fast transient disturbance tests:
• All ports
Surge immunity test:
• AC power input ports
Voltage dips and short interruptions
Emission tests:
• Conducted
0.15...0.50 MHz
0.5...5 MHz
5...30 MHz
• Radiated
30...230 Mhz
230...1000 MHz
1000...3000 MHz
3000...6000 MHz
18
Type test value
4 kV
4 kV
3 V (rms)
3 V/m (rms)
1 kV
2 kV, line-to-earth
1 kV, line-to-line
0 % / 1 cycle
40 % / 10 cycles
70 % / 25 cycles
< 66 dB(µV) quasi peak
< 56 dB(µV) average
< 56 dB(µV) quasi peak
< 46 dB(µV) average
< 60 dB(µV) quasi peak
< 50 dB(µV) average
< 35 dB(µV/m) quasi peak,
measured at 3 m distance
< 42 dB(µV/m) quasi peak,
measured at 3 m distance
< 70 dB(µV/m) quasi peak,
< 50 dB(µV/m) average,
measured at 3 m distance
< 74 dB(µV/m) quasi peak,
< 54 dB(µV/m) average,
measured at 3 m distance
1MRS757423 A
Reference
EN 61000-4-2
EN 61000-4-6
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-11
CISPR 22 (EN 55022), Class B
ABB

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rec601

Table of Contents