Maintenance & Service - Landa ECOS 7000 Operator's Manual

Pressure washer trailer system
Hide thumbs Also See for ECOS 7000:
Table of Contents

Advertisement

Burner Air Adjustment:
The oil burner on this machine is preset for operation
at altitudes below 1000 feet. If operated at higher
altitudes, it may be necessary to adjust the air band
setting. Adjust air band for a #1 or #2 smoke spot
on the Bacharach scale. If a smoky or eye-burning
exhaust is being emitted from the stack, two things
should be checked. First, check the fuel to be certain
that kerosene or No.1 home heating fuel is being used.
Next, check the air adjustment on the burner. An oily,
smoky fire indicates a lack of air and the air band
should be moved to allow the air to flow through the
burner. Sharp eye-burning fumes indicate too much
air flowing through the combustion chamber. The air
band should be readjusted to allow less air to flow
through the burner.
CAUTION: If white smoke appears from burner
exhaust vent during start-up or operation, discon-
tinue use and readjust air bands.
NOTE: If a flue is installed, have a professional ser-
viceman adjust your burner for a #1 or #2 smoke spot
on the Bacharach scale.
For additional burner component information, see
Burner Assembly Exploded View page . It is
recommended that the oil burner be serviced yearly or
as needed. Contact your local service center.
Beckett Burner Air Adjustment:
Air Shutter Locking
Screw
Air Shutter
Locking Screw
To adjust, start the machine and turn burner ON.
Loosen two locking screws found in the air shutter
openings (see illustration) and close air shutter until
black smoke appears from burner exhaust vent. Note
air band position. Next, slowly open the air shutter
until white smoke just starts to appear. Turn air shutter
halfway back to the black smoke position previously
noted. Tighten locking screws.
If the desired position cannot be obtained using only
the air shutter, lock the air shutter in as close a position
as can be obtained, then repeat the above procedure
on the air band setting.
26
MAINTENANCE & SERVICE
Air Shutter
Air Band
Air Band Locking
Screw
9.801-316.0 • Landa ECOS 7000 Operator Manual • Rev. 12/12
Landa Sure Fire Oil Burner
Reference Numbers
Air Band
Air Band Locking Screws
To adjust, start machine and turn burner ON. Loosen
two locking screws found on the air band and close air
band until black smoke appears from burner exhaust
vent. Note air band position. Next, slowly open the air
band until white smoke just starts to appear. Turn air
band halfway back to the previously noted position.
Tighten locking screws.
Sure Fire Burner Air Adjustment
Coil Removal
Coil removal, because of freeze breakage or to clean
soot from it, can be done quickly and easily.
1. Disconnect hose from pump to inlet side of coil.
2. Carefully disconnect the thermostat sensor making
sure you do not crimp the capillary tube.
3. Remove burner assembly from combustion
chamber.
4. Remove the 3-3/8" bolts from each side of coil and
tank assembly (these bolts are used to fasten tank
to chassis).
5. Remove fittings connected to the 1/2" pipe nipples
from inlet and discharge sides of coil.
6. Remove top tank wrap, bend back insulation tabs
and fold back blanket.
7. Remove bolts that hold down coil to bottom wrap.
8. Remove coil.
9. Replace or repair the coil and any insulation found
to be broken or torn.
10. Remove insulation retainer plates.
Coil Reinstallation
Reinstall new or cleaned coil reversing Steps 9
through 1.

Advertisement

Table of Contents
loading

Table of Contents