Valve Operation - Landa ECOS 7000 Operator's Manual

Pressure washer trailer system
Hide thumbs Also See for ECOS 7000:
Table of Contents

Advertisement

FROM UNLOADER
(BYPASS OUTLET)
TO 12V
FEED PUMP
FROM INNER
TANKS
18

VALVE OPERATION

BYPASS
VALVE
TO
INNER
TANKS
ON
INNER VALVE
OFF
FROM OUTER TANKS
9.801-316.0 • Landa ECOS 7000 Operator Manual • Rev. 12/12
With all tanks full, you
have the option of drawing
water from the two outer
tanks, the two inner tanks
or all four tanks.
OPTION 1: To draw water
from the outer tanks set
the outer tank valve to the
"ON" position and the in-
ner tank valve to the "Off"
position. Set the bypass
TO
valve to the outer tank
OUTER
position.
TANKS
OPTION 2: To draw water
from the inner tanks set
the outer tank valve to
the "OFF" position and
the inner tank valve to
the "ON" position. Set the
Bypass valve to the inner
ON
OUTER VALVE
OFF
tank position.
OPTION 3: To draw wa-
ter from all the tanks set
the outer and inner tank
valves to the "ON" posi-
tion. The bypass valve can
be in the inner or outer
tank position.
98013160-25