Siemens 6SE2101–1AA01 Operating Manual page 25

6se21 series simovert p
Table of Contents

Advertisement

Available languages

Available languages

Parameter
Parameter
Description
Number
Number
P06
VOLTAGE
(continued)
100
VOLTAGE
100
VOLTAGE
100
VOLTAGE
100
Curve type
P16
P07
Minimum frequency
P08
Maximum frequency
P09
Digital frequency set–point
adjustment
P10∗
Analogue frequency set–point
adjustment
Display
Setting
(Factory
Setting)
120
400
FREQUENCY
50
400
FREQUENCY
400
60
FREQUENCY
400
Knee Point
P15
FREQUENCY
00.0 –
399 Hz
00.1 –
400 Hz
00.0 –
400 Hz
(50.0)
080 –
240%
(100)
5/8
Notes
003
Linear 0–120 Hz
100% 120–400 Hz
004
Voltage
(frequency)
100% 50–400 Hz
Suitable for use with pumps and fans.
005
Voltage
(frequency)
100% 60–400 Hz
Suitable for use with pumps and fans.
006
User–defined curve.
When this value is selected, the 'knee point'
and curve type must be selected using
parameters P15 and P16.
(000)
[001]
Sets the minimum selectable operating
frequency. This is temporarily overridden
while starting or stopping the motor.
The Jog frequency may also be set below P07.
Notes: (1) With Tacho Mode (P30) = 001 or
003, the inverter will stop under
closed loop control until P37 <
P07 + 0.5 Hz.
(2) When the inverter ramps down
due to current overload, it will
trip with F00 when the output
frequency reaches P07.
(00.1)
Sets the required maximum frequency limit.
Note that the setting of this parameter will
affect the scaling of the analogue control
input (P04) and ramp rates P02 and P03.
(50.0)
[60.0]
This parameter sets the frequency to which
the inverter will run at startup when parameter
P04 has been set to 003 or higher. This value
may be updated automatically during
operation in certain operating modes selected
via P04.
[60.0]
This parameter allows the output frequency at
a given control voltage/current input to be
trimmed. Adjusting this parameter from 100(%)
to 080(%) will reduce the frequency
corresponding to an analogue input voltage of
10 V (or 20 mA) by a factor of 0.8. Setting the
parameter to 240(%) will increase the
frequency by a factor of 2.4.
English
1.5
0–50 Hz
1.5
0–60 Hz

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents