set-uP menu
To enter the set-up menu, use paper clip to press the small button
located below the Voltage Display on the case front.
Wire Feed Speed Units
To change the wire feed speed units:
Rotate the WFS knob to the left to use "inches/minute" for the
wire feed speed units.
Rotate the WFS knob to the right to use "meters/minute" for the
wire feed speed units.
Press the set-up button again to enter the Run-In menu.
Run-in
"Run-in" refers to the wire feed speed during the time from when
the trigger is pulled to when an arc is struck.
When Run-in is "ON", the wire feed speed is reduced until an arc
Model
Run-in Wire Feed Speed
K4267-1
50 in/min
When Run-in is "OFF", the wire feed speed is the same as the
welding wire feed speed. Turn Run-In "OFF" for fast, crisp starts,
especially when running with .035 or .045 (0.9 or 1.2mm) solid
steel wires at high wire feed speeds.
To change the Run-in setting:
run
run
Rotate the WFS knob to the left to turn Run-In OFF.
Rotate the WFS knob to the right to turn Run-In ON.
Press the set-up button again to enter the WFS calibration menu.
B-5
OPERATION
is struck.
Factory setting
is Run-In "OFF".