HIKVISION DS-7600NI-E1/E2 series User Manual page 129

Hide thumbs Also See for DS-7600NI-E1/E2 series:
Table of Contents

Advertisement

You must select during "Trigger Channel" settings the channel(s) you want to make full screen monitoring.
Audible Warning
Trigger an audible beep when an alarm is detected.
Notify Surveillance Center
Sends an exception or alarm signal to remote alarm host when an event occurs. The alarm host refers to the PC
installed with Remote Client.
The alarm signal will be transmitted automatically at detection mode when remote alarm host is configured. Please
错误
未找到引用源。
refer to Chapter
!
Email Linkage
Send an email with alarm information to a user or users when an alarm is detected.
Please refer to Chapter 11.2.8 for details of Email configuration.
Trigger Alarm Output
Trigger an alarm output when an alarm is triggered.
1. Enter Alarm Output interface.
Menu> Configuration> Alarm> Alarm Output
Select an alarm output and set alarm name and dwell time. Click Schedule button to set the arming schedule
of alarm output.
If "Manually Clear" is selected in the dropdown list of Dwell Time, you can clear it only by going to Menu>
Manual> Alarm.
2. Set up arming schedule of the alarm output.
Choose one day of a week and up to 8 time periods can be set within each day.
Time periods shall not be repeated or overlapped.
Network Video Recorder User Manual
错误!未找到引用源。 for details of alarm host configuration.
Figure 8. 16 Alarm Output Setup Interface
128

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents