B
C
B
A
Replacing the vacuum filter
Replacing the vacuum and pump fuses
Fig 52
Maintenance
Certain components are located in the bottom of the
machine (Fig 49).
Vacuum filter housing.
Mains 6.3 amp time lag fuse holder x 2.
Plugged cable.
Always ensure the machine has been unplugged
from the electric supply BEFORE attempting any
repairs.
Fig 49
To gain access to this filter remove the filter cover (Fig 50).
Periodically, clean or renew the filter
using (207119) Vacuum filter
It is recommended you only use genuine NUMATIC parts.
Fig 50
Under the rectangular plate is 6.3 amp time lag fuse holder
Remove the plate (Fig 51).
B
Fuse
Replace using (220179) 6.3 amp time lag fuses (Fig 54).
It is recommended you only use genuine NUMATIC parts.
Fig 51
Fig 53
18
A
C
(See fig 52) is the mains fuse x 2.
Fig 54
B