Table A - ASL3 & ASL5
Catalog
Length
Watts
Total
Number
"L"
per ft.
Watts
02100
100
200
02125
28"
125
250
02150
(711mm)
150
300
02188
188
376
02250
250
500
03100
100
300
03125
3'
125
375
03150
(914mm)
150
450
03188
188
564
03250
250
750
04100
100
400
04125
4'
125
500
04150
(1219mm)
150
600
04188
188
752
04250
250
1000
05100
100
500
05125
5'
125
625
05150
(1524mm)
150
750
05188
188
940
05250
250
1250
06100
100
600
06125
6'
125
750
06150
(1829mm)
150
900
06188
188
1128
06250
250
1500
07100
100
700
07125
7'
125
875
07150
(2134mm)
150
1050
07188
188
1316
07250
250
1750
08100
100
800
08125
8'
125
1000
08150
(2438mm)
150
1200
08188
188
1504
08250
250
2000
09100
100
900
09125
9'
125
1125
09150
(2743mm)
150
1350
09188
188
1692
09250
250
2250
10100
100
1000
10125
10'
125
1250
10150
(3048mm)
150
1500
10188
188
1880
10250
250
2500
Clearance Chart:
For safe and efficient operation, maintain at least the following
minimum clearances at all times:
Bottom of Heater to Finished Floor:
• Front Inlet Models: (max 600 watts per foot)
- May be installed on floor. However, for best performance,
install bottom of heater approximately 3 inches (76 mm) off floor.
• Bottom Inlet Models:
- 100-250 watts per foot – 1-3/4 inch (44 mm)
- 375-750 watts per foot – 3 inches (76 mm)
Top of Heater to Ceiling (all models):
- Minimum 36 inches (914 mm)
Top of Heater to Bottom of Drapes Above Heater:
- Minimum 12 inches (305 mm)
Table C. Maximum Length of Heater Run
Watts/Ft
of
120V
Heaters
1 Ph
1 Ph
100
54 (16)
93 (28)
125
43 (13)
74 (23)
150
36 (11)
62 (19)
188
28 (9)
49 (15)
250
21 (6)
37 (11)
375
-
34 (7)
500
-
18 (5)
600
-
15 (5)
750
-
12 (4)
(one element)
Amperage
120V
208V
240V
277V
347V
1.7
1.0
0.8
--
--
2.1
1.2
1.0
0.9
--
2.5
1.4
1.3
1.1
--
3.1
1.8
1.6
1.4
--
4.2
2.4
2.1
1.8
1.4
2.5
1.4
1.3
1.1
--
3.1
1.8
1.6
1.4
1.1
3.8
2.2
1.9
1.6
1.3
4.7
2.7
2.4
2.0
1.6
6.3
3.6
3.1
2.7
2.2
3.3
1.9
1.7
1.4
1.2
4.2
2.4
2.1
1.8
1.4
5.0
2.9
2.5
2.2
1.7
6.3
3.6
3.1
2.7
2.2
8.3
4.8
4.2
3.6
2.9
4.2
2.4
2.1
1.8
1.4
5.2
3.0
2.6
2.3
1.8
6.3
3.6
3.1
2.7
2.2
7.8
4.5
3.9
3.4
2.7
10.4
6.0
5.2
4.5
3.6
5.0
2.9
2.5
2.2
1.7
6.3
3.6
3.1
2.7
2.2
7.5
4.3
3.8
3.2
2.6
9.4
5.4
4.7
4.1
3.3
12.5
7.2
6.3
5.4
4.3
--
3.4
2.9
2.5
2.0
--
4.2
3.6
3.2
2.5
--
5.0
4.4
3.8
3.0
--
6.3
5.5
4.8
3.8
--
8.4
7.3
6.3
5.0
--
3.8
3.3
2.9
2.3
--
4.8
4.2
3.6
2.9
--
5.8
5.0
4.3
3.5
--
7.2
6.3
5.4
4.3
--
9.6
8.3
7.2
5.8
--
4.3
3.8
3.2
2.6
--
5.4
4.7
4.1
3.2
--
6.5
5.6
4.9
3.9
--
8.1
7.1
6.1
4.9
--
10.8
9.4
8.1
6.5
--
4.8
4.2
3.6
2.9
--
6.0
5.2
4.5
3.6
--
7.2
6.3
5.4
4.3
--
9.0
7.8
6.8
5.4
--
12.0
10.4
9.0
7.2
Max. allowable length of heater run in feet (meters)
208V
3 Ph
1 Ph
-
108 (33)
-
86 (26)
-
72 (22)
-
57 (17)
-
43 (13)
-
28 (9)
-
21 (6)
27 (8)
18 (5)
21 (6)
14 (4)
ASL5
(two and three element)
Catalog
Length
Watts
600V
Number
"L"
per ft. Watts 1 Ph 3 Ph
--
02375
375
--
02500
28"
500
--
02600
(711mm)
600
--
02750*
750
--
03375
375
--
03500
3'
500
--
--
03600
(914mm)
600
03750*
750
--
04375
375
--
04500
4'
500
--
04600
(1219mm)
600
--
04750*
750
--
05375
375
1.3
05500
5'
500
1.7
05600
(1524mm)
600
0.8
05750*
750
1.0
06375
375
1.3
06500
6'
500
1.6
06600
(1829mm)
600
2.1
06750*
750
1.0
07375
375
1.3
07500
7'
500
1.5
1.9
07600
(2134mm)
600
07750*
750
2.5
08375
375
1.2
08500
8'
500
1.5
08600
(2438mm)
600
1.8
2.2
08750*
750
09375
375
2.9
09500
9'
500
1.3
09600
(2743mm)
600
1.7
09750*
750
2.0
10375
375
2.5
10500
10'
500
3.3
10600
(3048mm)
600
1.5
10750*
750
1.9
2.3
*Bottom inlet only
2.8
3.8
IMPORTANT NOTE: Certain fabrics and vinyl materials (such
1.7
2.1
as vinyl blinds) may become damaged by the heated air from
2.5
the heater and should not be installed above the heater.
3.1
4.2
Front of Heater to Full Length Drapes in Front of Heater:
- Minimum between bottom of drapes and floor – 2-1/2 inches
(64 mm)
- Minimum between top of drapes and ceiling – 1/2 inch (13
mm)
- Minimum between front of heater and nearest fold of drape –
2 inches (51 mm)
Top of Heater to Bottom of Window Sill:
- Minimum 12 inches (305 mm)
Table B. Sizing Field Installed Wiring
Max. No.
wire installed
Copper wire
size 90º C
in wireway
No. 12 AWG
No. 10 AWG
No. 8 AWG
240V
277V
3 Ph
1 Ph
-
124 (38)
-
99 (30)
-
83 (25)
-
66 (20)
-
49 (15)
-
33 (10)
-
24 (7)
31 (9)
20 (6)
24 (7)
16 (5)
2
Amperage
Total
208V
240V
277V
1 Ph
3 Ph
1 Ph
750
3.6
-
3.1
-
1000
4.8
-
4.2
-
1200
5.8
3.3
5.0
2.9
1500
7.2
4.2
6.3
3.6
1125
5.4
-
4.7
-
1500
7.2
-
6.3
-
1800
8.7
5.0
7.5
4.3
2250
10.8
6.3
9.4
5.4
1500
7.2
-
6.3
-
2000
9.6
-
8.3
-
2400
11.5
6.7
10.0
5.8
3000
14.4
8.3
12.5
7.2
10.8
1875
9.0
-
7.8
-
2500
12.0
-
10.4
-
3000
14.4
8.3
12.5
7.2
10.8
3750
18.0 10.4
15.6
9.0
13.5
2250
10.8
-
9.4
-
3000
14.4
-
12.5
-
10.8
3600
17.3 10.0
15.0
8.7
13.0
4500
21.6 12.5
18.8
10.8
16.2
2625
12.6
-
10.9
-
3500
16.8
-
14.6
-
12.6
4200
20.2 11.7
17.5
10.1
15.2
5250
25.2 14.6
21.9
12.6
19.0
3000
14.4
-
12.5
-
10.8
4000
19.2
-
16.7
-
14.4
4800
23.1 13.3
20.0
11.6
17.3
6000
28.8 16.7
25.0
14.5
21.7
3375
16.2
-
14.1
-
12.2
4500
21.6
-
18.8
-
16.2
5400
26.0 15.0
22.5
13.0
19.5
6750
32.5 18.8
28.1
16.3
24.4
3750
18.0
-
15.6
-
13.5
5000
24.0
-
20.8
-
18.1
6000
28.8 16.7
25.0
14.5
21.7
7500
36.1 20.8
31.3
18.1
27.1
Maximum Allowable Current
Up to 3
4 to 6
conductors
conductors
9
11.5 Amps
9.3 Amps
8
17.4 Amps
14.0 Amps
4
24.0 Amps
21.0 Amps
347V
1 Ph
1 Ph
156 (47)
270 (82)
125 (38)
216 (66)
104 (32)
180 (55)
83 (25)
146 (45)
62 (19)
108 (33)
42 (13)
72 (22)
31 (9)
54 (16)
26 (8)
45 (14)
21 (6)
36 (11)
347V
600V
1 Ph
1 Ph
3 Ph
2.7
-
-
-
3.6
2.9
-
-
4.3
-
-
-
5.4
4.3
-
-
4.1
-
-
-
5.4
4.3
-
-
6.5
-
-
-
8.1
6.5
-
-
5.4
4.3
-
-
7.2
5.8
3.3
-
8.7
6.9
-
-
8.6
5.0
2.9
6.8
5.4
3.1
-
9.0
7.2
4.2
-
8.6
5.0
2.9
10.8
6.3
3.6
8.1
6.5
3.8
-
8.6
5.0
-
10.4
6.0
3.5
13.0
7.5
4.3
9.5
7.6
4.4
-
10.1
5.8
-
12.1
7.0
4.0
15.1
8.8
5.1
8.6
5.0
-
11.5
6.7
-
13.8
8.0
4.6
17.3
10.0
5.8
9.7
5.6
-
13.0
7.5
-
15.6
9.0
5.2
19.5
11.3
6.5
10.8
6.3
-
14.4
8.3
-
17.3
10.0
5.8
21.6
12.5
7.2
7 to 9
conductors
8.1 Amps
12.1 Amps
-
600V
3 Ph
467 (142)
373 (113)
311 (95)
248 (76)
186 (57)
125 (38)
93 (28)
78 (24)
62 (19)