Download Print this page
Berko FRA series Installation And Maintenance Instructions

Berko FRA series Installation And Maintenance Instructions

Fan forced

Advertisement

Quick Links

FRA Series
Fan Forced
Wall Heaters
Watts
Volts
4000
208
4000
240
4800
208
4800
240
4800
208
Installation & Maintenance Instructions
Dear Owner,
Congratulations! Thank you for purchasing this new heater manufactured by a division of Marley
Engineered Products. You have made a wise investment selecting the highest quality product in the heat-
ing industry. Please carefully read the installation and maintenance directions shown in this manual.
You should enjoy years of efficient heating comfort with this product from Marley Engineered Products...
the industry's leader in design, manufacturing, quality and service.
Read Carefully
- These instructions are written to help
you prevent difficulties that might arise during installation of
heaters. Studying the instructions first may save you con-
siderable time and money later. Observe the following pro-
cedures and cut your installation time to a minimum.
1. To prevent electrical shock, disconnect all power coming
to heater at main service panel before wiring or servicing.
2. All wiring must be in accordance with the National and
Local Electrical Codes and the heater must be grounded
as a precaution against possible electric shock.
3. Verify the power supply voltage coming to heater match-
es the ratings printed on the heater nameplate before
energizing.
4. This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces.
Ph
3
3
3
3
1
WARNING
!
5. Do not insert or allow foreign objects to enter any ventila-
6. To prevent a possible fire, do not block air intakes or
7. A heater has hot and arcing (sparking) parts inside. Do
8. Use this heater only as described in this manual. Any
9. This heater is not approved for use in corrosive atmos-

SAVE THESE INSTRUCTIONS

1
FILE #E21609
... The Employees of
Marley Engineered Products
tion or exhaust opening as this may cause an electric
shock, fire, or damage to the heater.
exhaust in any manner. Keep combustible materials, such
as crates, drapes, etc., away from heater. Do not install
behind doors, furniture, towels, or boxes.
not use it in areas where gasoline, paint, or flammable
liquids are stored.
other use not recommended by the manufacturer may
cause fire, electric shock, or injury to persons.
pheres, such as marine, green house, or chemical stor-
age areas.

Advertisement

loading

Summary of Contents for Berko FRA series

  • Page 1: Save These Instructions

    FRA Series Fan Forced Wall Heaters Watts Volts 4000 4000 4800 4800 4800 FILE #E21609 Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater manufactured by a division of Marley Engineered Products. You have made a wise investment selecting the highest quality product in the heat- ing industry.
  • Page 2 Installation of Recessed Wall Housing IMPORTANT in Existing Construction 1. Provide a wall opening 14-1/2" (362mm) wide by 18-1/2" (470mm) high at the desired mounting height, but no WARNING closer than 8" (203mm) from floor. (See Figure 2.) 2. Power Supply Wiring Note: Wiring Compartment Volume - 119in (1950cm DO NOT INSTALL HEATER UPSIDE DOWN OR SIDE-...
  • Page 3 Installation of Housing with Surface-Mounting Frame (See Figure 3) POWER LEADS BACK BOX DISCONNECT SWITCH 1. Secure back box to wall with knockouts in upper right hand corner using screws and anchors. PLASTIC COVER 2. Hang the surface-mounting frame on the back box. INNER FRAME ASSEMBLY Ensure that the back edge of the surface-mounting frame...
  • Page 4: How To Order Repair Parts

    Operation and marked “reset”. The red reset button can be seen through the front grille when the heater is installed. To reset, 1. Rotate the thermostat fully clockwise. This should allow the heater to cool, then push the red button that is vis- energize the heating elements and cause warm air to ible through the hole in the fan panel.