Vent
Height
H
(feet)
FAN + FAN
6
92
8
101
10
110
15
125
20
136
30
152
Removal of the Furnace from Common Vent
In the event that an existing furnace is removed from a
venting system commonly run with separate gas applianc-
es, the venting system is likely to be too large to properly
vent the remaining attached appliances.
Conduct the following test while each appliance is oper-
ating and the other appliances (which are not operating)
remain connected to the common venting system. If the
venting system has been installed improperly, you must
correct the system as indicated in the general venting re-
quirements section.
Vent Connector Capacity
Type B Double-Wall Vents with Type B Double-Wall Connectors
Serving Two or More Category I Appliances
3 inch
Min
Max
22
37
23
41
24
44
22
40
23
44
24
47
22
43
23
47
24
50
21
50
22
53
24
55
21
54
2
57
23
60
20
62
21
64
22
66
Common Vent Capacity
Type B Double-Wall Vents with Type B Double-Wall Connectors
Serving Two or More Category I Appliances
4 inch
Appliance Input Rating in Thousands of Btu Per Hour
FAN + NAT
FAN + FAN
81
140
90
155
97
169
112
195
123
215
138
244
TABLE 4
Vent and Connector Diameter - D (inches)
4 inch
Appliance Input Rating in Thousands of Btu Per Hour
Min
Max
35
66
37
75
38
81
35
72
36
80
37
87
34
78
36
86
37
92
33
89
35
96
36
102
33
99
34
105
35
110
31
113
33
118
34
123
TABLE 5
Vent and Connector Diameter - D (inches)
5 inch
FAN + NAT
FAN + FAN
116
204
129
224
141
243
164
283
183
314
210
361
CARBON MONOXIDE POISONING HAZARD
Failure to follow the steps outlined below for each
appliance connected to the venting system being
placed into operation could result in carbon monoxide
poisoning or death. The following steps shall be
followed for each appliance connected to the venting
system being placed into operation, while all other
appliances connected to the venting system are not in
operation:
Page 19
5 inch
Min
Max
46
106
48
121
49
132
49
114
51
128
53
139
49
123
51
136
52
146
47
142
49
153
51
163
46
157
48
167
50
176
45
181
47
190
48
198
7 inch
FAN + NAT
FAN + FAN
161
309
178
339
194
367
228
427
255
475
297
547
IMPORTANT
6 inch
Min
Max
58
164
60
183
62
199
64
176
66
195
67
210
65
189
67
206
69
220
64
220
66
235
68
248
62
246
64
259
66
271
60
288
62
299
64
309
7 inch
FAN + NAT
248
275
299
352
394
459