8. Compressed Air System
8.3.2
Oil and water separator (3S01)
An oil and water separator should always be installed in the pipe between the compressor
and the air vessel. Depending on the operation conditions of the installation, an oil and water
separator may be needed in the pipe between the air vessel and the engine.
8.3.3
Starting air vessel (3T01)
The starting air vessels should be dimensioned for a nominal pressure of 3 MPa.
The number and the capacity of the air vessels for propulsion engines depend on the
requirements of the classification societies and the type of installation.
It is recommended to use a minimum air pressure of 1.8 MPa, when calculating the required
volume of the vessels.
The starting air vessels are to be equipped with at least a manual valve for condensate drain.
If the air vessels are mounted horizontally, there must be an inclination of 3...5° towards the
drain valve to ensure efficient draining.
Fig 8-3
The starting air consumption stated in technical data is for a successful start. During start the
main starting valve is kept open until the engine starts, or until the max. time for the starting
attempt has elapsed. A failed start can consume two times the air volume stated in technical
data. If the ship has a class notation for unattended machinery spaces, then the starts are to
be demonstrated.
The required total starting air vessel volume can be calculated using the formula:
8-4
Starting air vessel
Size
Dimensions [mm]
[Litres]
L1
L2
1)
250
1767
243
500
3204
243
710
2740
255
1000
3560
255
1250
2930
255
1)
Dimensions are approximate.
Wärtsilä 31 Product Guide - a1 - 18 October 2016
Wärtsilä 31 Product Guide
Weight
[kg]
L3
1)
D
110
480
274
133
480
450
133
650
625
133
650
810
133
800
980