1. Main Data and Outputs
1.2

Reference conditions

The output is available up to a charge air coolant temperature of max. 38°C and an air
temperature of max. 45°C. For higher temperatures, the output has to be reduced according
to the formula stated in ISO 3046-1:2002 (E).
The specific fuel oil consumption is stated in the chapter Technical data. The stated specific
fuel oil consumption applies to engines with engine driven pumps, operating in ambient
conditions according to ISO 15550:2002 (E). The ISO standard reference conditions are:
Correction factors for the fuel oil consumption in other ambient conditions are given in standard
ISO 3046-1:2002.
1.3

Operation in inclined position

Max. inclination angles at which the engine will operate satisfactorily.
Table 1-2
● Transverse inclination, permanent (list)
● Transverse inclination, momentary (roll)
● Longitudinal inclination, permanent (trim)
● Longitudinal inclination, momentary (pitch)
1-2
total barometric pressure
air temperature
relative humidity
charge air coolant temperature
Inclination with Normal Oil Sump
Inclination in all directions requires special arrangements.
100 kPa
25°C
30%
25°C
15°
22.5°
10°
10°