Wartsila 31 Product Manual page 65

Table of Contents

Advertisement

Wärtsilä 31 Product Guide
Design data:
Capacity
Design pressure
Max. total pressure (safety valve)
Design temperature
Viscosity for dimensioning of electric motor
Pressure control valve, booster unit (1V03)
The pressure control valve in the feeder/booster unit maintains the pressure in the de-aeration
tank by directing the surplus flow to the suction side of the feed pump.
Design data:
Capacity
Design pressure
Design temperature
Set-point
Fine filter (1F05)
The fuel oil fine filter is a full flow duplex type filter with steel net. This filter must be installed
as near the engine as possible.
The diameter of the pipe between the fine filter and the engine should be the same as the
diameter before the filters.
Design data:
Fuel viscosity
Design temperature
Design flow
Design pressure
Fineness
Maximum permitted pressure drops at 14 cSt:
- clean filter
- alarm
Automatic filter, booster unit (1F08)
It is recommended to select an automatic filter with a manually cleaned filter in the bypass
line. The automatic filter must be installed before the heater, between the feed pump and the
de-aeration tank, and it should be equipped with a heating jacket. Overheating (temperature
exceeding 100°C) is however to be prevented, and it must be possible to switch off the heating
for operation on MDF.
Design data:
Wärtsilä 31 Product Guide - a1 - 18 October 2016
Total consumption of the connected engines added with
the flush quantity of the automatic filter (1F08)
1.6 MPa (16 bar)
0.7 MPa (7 bar)
100°C
1000 cSt
Equal to feed pump
1.6 MPa (16 bar)
100°C
0.3...0.5 MPa (3...5 bar)
according to fuel specifications
100°C
Larger than feed/circulation pump capacity
1.6 MPa (16 bar)
25 μm (absolute mesh size)
20 kPa (0.2 bar)
80 kPa (0.8 bar)
6. Fuel Oil System
6-21

Hide quick links: