Description Of The Appliance; Electrical Connection And Operation - Whirlpool 3XRA700-JWARG480PW01 Repair Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
English
KNOW YOUR FROST-FREE
APPLIANCE
The main advantage of your refrigerator/freezer
with fan circu-
lation is the total absence of frost and ice forming on the com-
partments walls, thanks to the process described below. The
cold air is produced
by an evaporator
and is circulated
by
means of a fan into the two compartments.
The air, having been
circulated, is again passed to the evaporator. This keeps the
humidity low. In this way, there will be no frost formation on the
compartment
walls, as in a traditional appliance.
The "ventilated cold" system ensures a better storage of foods
maintaining
their original condition
for a longer period of
time.
DESCRIPTION
OF THE APPLIANCE
(Fig. 1)
- Control panel with:
1) Freezer compartment
temperature control knob
2) Refrigerator compartment
temperature control knob
3) Exterior moisture control
4) Light control button of the refrigerator compartment
- Freezer
compartment
A) Fast freeze compartment
(if provided)
B) Automatic ice maker
C) Ice storage bin
D) Interior light
E) Automatic ice and water dispensers
(outer - removable)
F) Baskets
G) Adjustable shelves
- Refrigerator
compartment
H) Interior light
I) Rating plate
L) Butter and dairy produces compartment
M) Bottles rack
N) Shelves
0) Snack rack
P) Adjustable
shelves
Q) Crispers with humidity controls
R) Meat drawer with temperature
control
S) Plinth
T) Levelling rollers
INSTALLATION
(Fig. 2)
Please check your appliance and ensure that it is undamaged;
any transport damage must be reported to your dealer within
24 hours of receipt.
The appliance
should not be installed close to heat sources
such as cookers, central heating boilers, direct sunlight, etc.; it
must however be located in a well ventilated dry space. If the
appliance is to be installed next to kitchen furniture, there must
be a 1.5 cm gap at the sides.
Position it as follows:
- remove the base grille by pulling it outwards (Fig. 3) (do not
remove the Tech Sheet fastened behind the grille);
- level the appliance by means of screw A (Fig. 4). To raise turn
screw clockwise, to lower turn screw anti-clockwise;
Remount the grille as follows:
1. line up the grille support tabs C with the metal clips D;
2. push firmly to snap into place.
Clean the interior with a sponge dampened in a solution of luke-
warm water and bicarbonate
of soda or vinegar.
Clean the exterior with a sponge dampened
in a solution of
lukewarm water and dry with a soft cloth.
Do not use abrasives, detergents or harsh cleansers.
The hydraulic connections
instructions for the automatic ice-
maker are given on the separate leaflet.
ELECTRICAL
CONNECTION
AND OPERATION
This appliance
conforms
to EEC directive
82/499 on radio
interference.
Leave the appliance to stand for one hour before connecting it
to the electricity supply. Please check that the voltage on the
rating plate (Fig. 5) situated under the control panel, corre-
sponds to the voltage in your home.
The earthing
of this appliance
is compulsory
by law.
The Manufacturer will accept no liability for damage to persons
or objects arising from the non-observance
of this requirement.
Connect the appliance to the supply by means of the plug: the
interior lights switch on when the doors are opened.
Some hours are necessary to attain the correct storage tempe-
ratures in the appliance.
FOR UK ONLY'
"WARNING:
THIS APPLIANCE
MUST BE EARTHED"
IMPORTANT:
The wires of the mains lead fitted to this
appliance
are coloured
in accordance
with the following
code:
GREEN AND YELLOW-EARTH
BLUE-NEUTRAL
BROWN-LIVE
As the colours of the wires in the mains lead fitted to this
appliance
may not correspond
with the coloured
markings
identifying the terminals in the plug, proceed as follows:
The wire which is coloured GREEN AND YELLOW must be
connected to the terminal in the plug which is marked with the
letter 'E' or by the earth symbol
GREEN AND YELLOW.
+
or coloured GREEN or
The wire which is coloured BLUE must be connected to the ter-
minal which
is marked
with the letter 'N' or coloured
BLACK.
The wire which is coloured BROWN must be connected to the
terminal which is marked with the letter 'L' or coloured RED. If
the terminals in the plug are unmarked or you are in any doubt
as to the correct connections,
consult a qualified electrician.
N.B.: We recommend the use of a good quality plug.
For the Republic
or Ireland only
The information given in respect of Great Britain will frequently
apply, but a third type of plug and socket is also used, the 2-pin,
side earth type. In this case, the wire which is coloured GREEN
AND YELLOW must be connected to the EARTH contact, and
the other two wires to the pins, irrespective of colour. The sup-
ply to the socket must be fitted with a 16 Amp fuse.