BAdjusting King-pin Pivot
Loosen the lock nut and tighten the adjusting screw with
following torque:
Adjusting screw
4.9 to 9.8 N-m, 3.6 to 7.2 ft-lbs
Lock nut
98.1 to 147 N-m, 72.4 to 108.4 ft-lbs
(1) Adjusting screw
(2) Lock nut

EVERY 1000 HOURS

BChanging Transmission Fluid
To avoid personal injury or death:
A Allow engine to cool down sufficiently, oil can
be hot and can burn.
1. To drain the used oil, remove the drain plug at the
bottom of the transmission case and drain the oil
completely into the oil pan.
Clean the magnetic plug with rags.
2. After draining reinstall the drain plug.
3. Fill with the new KUBOTA SUPER UDT fluid up to the
upper notch on the dipstick.
(See "LUBRICANTS" in "MAINTENANCE" section.)
4. After running the engine for a few minutes, stop it and
check the oil level again; add oil to prescribed level.
Oil capacity
65 L (68.7 U.S.qts)
(1) Drain plugs
(2) Magnetic plug (wipe off metal filings)
(1) Dipstick
(2) Oil filling plug
A Do not operate the tractor immediately after changing
the transmission fluid.
Run the engine at medium speed for a few minutes to
prevent damage to the transmission.
(A) Oil level is acceptable within
this range