3. TECHNICAL BRIEF
1.
Charging method : CC-CV(pulse charging)
2.
Charger detect voltage : 5.0 V
3.
Charging time : 2h 40m
4.
Charging current : 610 mA
5.
CV voltage : 4.1 V
6.
Cutoff current : below 60 mA
7.
Full charge indication current (icon stop current) : 60 mA
8.
Recharge voltage : 4.15 V
9. Low battery alarm
a. Idle : below 3.55 V
b. call : below 3.55 V
10. Low battery alarm interval
a. Idle : 3 min
b. Dedicated : 1 min
11. Switch-off voltage : 3.3 V
12. Charging temperature adc range
a. ~ -20
: low charging voltage operation (3.6 V ~ 3.8 V) .
b. -20
~ 60
: standard charging (up to 4.2 V)
c. 60 ~ : low charging voltage operation (3.6V ~ 3.8V)
LGE Internal Use Only