Only For Training And Service Purposes - LG -S310 Service Manual

Hide thumbs Also See for LG-S310:
Table of Contents

Advertisement

3. TECHNICAL BRIEF
3.2.4 Front End Module(LMSP4DNA-883)
SAW front end module for mobile telephone systems
Covering GSM850, GSM900, GSM1800, GSM1900 bands
Integration of GSM 850, EGSM, DCS, PCS RX SAWs
Balanced outputs of all RX ports
FEM(FL101) has two logic inputs, which are VC1, VC2, for selecting RX/TX-mode and low/high-band operation
ANT_FEED
LGE Internal Use Only
[Table 3.2.4-1] FEM control logic
GND
RF_ANT_SW2
RF_ANT_SW1
C124
100p
SW101
G2
ANT
RF
G1
[Figure 3.2.4-1] FEM schematic
FL101
836.5 ,1880MHz
NC2
20
NC1
GSM850_900TX
19
15
GSM1800_1900TX
11
GND5
18
GND4
GSM1900RX2
16
8
GND3
GSM1900RX1
13
7
GND2
GSM1800RX2
12
6
GND1
GSM1800RX1
9
5
GSM900RX2
4
VC2
GSM900RX1
10
3
VC1
GSM850RX2
14
2
GSM850RX1
1
C125
100p
C129 100p
L102
100n
- 18 -
Copyright © 2010 LG Electronics. Inc. All right reserved.
C114
100p
100p
C117

Only for training and service purposes

Advertisement

Table of Contents
loading