Service Testprogram; Various Tests - Philips CDR796 Service Manual

Philips compact disc recorder service manual
Hide thumbs Also See for CDR796:
Table of Contents

Advertisement

SERVICE TESTPROGRAM

VARIOUS TESTS

END-USER DIAGNOSTICS
(CDR module)
To enter
END-USER DIAGNOSTICS
hold S & T buttons
on CDR side depressed
while plugging mainscord in.
DISPLAY TEST
N
DISPLAY button
pressed?
Display shows for 5s each:
• Software version of set P
S-CDR795-VXX
Display shows
all segments and flags
S
stands for Service mode
for checking open circuits.
VXX
see figure 1
stands for Version
number of the software used
All LEDs are switched on.
in the Front (Display) P.
• Software versions of the
CDR module:
MOXXXX BXXXX
N
STOP button
pressed?
MOXXXX
stands for
Software version of
MOZART flash ROM 7101
BXXXX
stands for
Software version of
Basic Engine
flash EPROM 7017
SDRAM TEST 7100
Display shows:
DTST1
CHECKSUM TEST 7101
Display shows:
DTST2
ERASE TEST 7101
Display shows:
DTST3
COMMUNICATION TEST
(UART-BUS)
Display shows:
DTST4
N
Y
TEST O.K.?
Display shows
NEW
for 2s.
EEPROM is cleared
and default values
are stored.
Display shows:
Display shows:
FAILED
PASSED
for 3s.
for 3s.
EXIT
END-USER DIAGNOSTICS
5-7
SERVICE TESTPROGRAM
VARIOUS TESTS
QUARTZ TEST
KEY TEST
N
SPEED button
pressed?
Y
Y
Tact frequency P
(divided 10MHz)
Display shows
10M
1220 37Hz can be measur.
on
f
(pin 23 of P).
0
STOP button
N
pressed?
Y
Y
STEP ALBUM
PLAYLIST
MP3
TIME
TRACK
REP TRACK DISC ALL PROG SHUFF
CD PLAYER
L
1X
2X
DIG
LINE
4X
8X
OPTMIC
R
fig. 1
To enter Service
Testprogram hold
PLAY & REC buttons
depressed while
plugging mainscord in.
Display shows
version number
of the P - software.
S-CDR795-VXX
FORMAT EEPROM
N
N
SHUFFLE button
CD
ALBUM - button
pressed?
pressed?
Y
Y
Display shows
Display shows
KEY --
NEW
Numbers acc. table 2
for 2s.
are indicated as long as a
EEPROM is cleared and
button is held depressed.
default values are stored.
If a button is pressed
on the Remote Control
KEY RC is shown
This test should only be used to clear
and the ; flag flashes.
the EEPROM in case of a P-"hangup".
Attention: all data are set to default values,
BLACK BOX data are not cleared.
N
CD
STOP button
pressed?
Y
TOTAL
REM
REC
TRACK
TIME
CD RECORDER
CDTEXT
CD
R W
REC
EDIT
FINALIZE
5-7
* To leave Service Testprogram plug mains cord off.
* In the main menu the sound settings (volume, ...)
and trays work as in normal mode.
S
stands for Service mode
VXX
stands for Version number
of the software used in the
Front (Display) P.
EEPROM TEST
N
INPUT button
pressed?
Y
Testpattern is written to
address 1
and
read back again
N
Test ok?
Y
Display shows
Display shows
ERR
PASS
STOP button
N
pressed?
Y
KEY CODES
KEY
KEY CODE
KEY
KEY CODE
OPEN/CLOSE
0
ERASE CD
12
(CD)
PLAY/PAUSE
STANDBY
1
13
(CDR)
STOP
SPEED
2
14
(CDR)
PLAY/PAUSE
ALBUM -
3
15
(CD)
(CDR)
STOP
ALBUM +
4 (exit)
16
(CD)
(CDR)
ALBUM -
S
5
17
(CD)
(CDR)
ALBUM +
T
6
18
(CD)
(CDR)
S
7
RECORD
19
(CD)
T
8
COPY CD
20
(CD)
OPEN/CLOSE
DISPLAY
9
21
(CDR)
SHUFFLE
10
INPUT
11
table 2
TEMPERATURE
(NTC) TEST
STANDBY button
N
pressed?
Y
Display shows
NTC XX
XX = value in C
N
N
STANDBY button
STOP button
pressed?
pressed?
Y
Y
Fan is switched on/off
display shows
FAN ON
or
FAN OFF
for 2s.
CDR79x servtest various, 240402

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdr795Cdr796/00sCdr795/00Cdr795/17

Table of Contents