Serai KIT/30 F Installation Manual

2 motors for swing gates

Advertisement

S
KIT/30 F -
SR 03.32 F -
KIT/39 F -
SR 02.39 F -
Thank you for choosing a SERAI ELETTRONICA product, which we are confident will perform to your requirements.
Please be advised that you are about to fit a system classified as "a power-operated drive designed to move automatic ga-
tes and doors in commercial or residential buildings accessed by vehicles and persons", and as such, the system must be
considered potentially hazardous. By law, you are responsible for rendering this equipment as "safe" as is reasonably pos-
sible.
Installation and maintenance of equipment of this kind must therefore be carried out by skilled, qualified and trained
personnel, working in a professional manner, as provided for by law n. 37/08 and any subsequent amendments and
supplements. The law in question prohibits the construction of these types of systems by non-qualified personnel.
SERAI manufacturing complies with the following legislation:
Applicable directives for the CE marking :
Machines:
Low Voltage:
Electromagnetic Compatibility:
General applicable standards:
Electrical Safety:
Electromagnetic Compatibility - Emissions:
Electromagnetic Compatibility - Immunity:
Apart from the legislation mentioned above, you are also reminded to comply with the following standards during the
installation phase.
General applicable standards:
Safety of electrical systems in non-specialised environments:
Specific product standards applicable:
Safety in the use of power-operated doors - requirements:
Safety in the use of power-operated doors - testing methods:
SERAI products enable users to build systems which comply with these standards. This is extremely important as
!
THE INSTALLER IS LIABLE FOR THE SYSTEM AND FOR ENSURING ITS OPERATION COMPLIES WITH
LEGAL PROVISIONS.
This handbook must be read in full before proceeding with the installation of the various parts of the system.
The installation of the mechanical end stops for gate opening and closure is necessary for system safety purposes
and therefore this operation must be performed before proceeding with the installation of the control unit.
E
INSTALLATION MANUAL
KIT WITH 2 MOTORS FOR SWING GATES UP TO 3.0 + 3.0 METERS AND
300 kg PER LEAF - 230 Vac
KIT WITH 2 MOTORS FOR SWING GATES UP TO 2.0 + 2.0 METERS AND
200 kg PER LEAF - 230 Vac
R
A
GATE AUTOMATION DIVISION
2006/42/EC
2006/95/EEC
2004/108/EEC
IEC EN60335-1 + IEC EN60335-2-103
CEI EN61000-6-3
CEI EN61000-6-
CEI 64-8 V2
UNI EN12453
UNI EN12445
I
Page 1/18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KIT/30 F and is the answer not in the manual?

Questions and answers

Summary of Contents for Serai KIT/30 F

  • Page 1 200 kg PER LEAF - 230 Vac Thank you for choosing a SERAI ELETTRONICA product, which we are confident will perform to your requirements. Please be advised that you are about to fit a system classified as “a power-operated drive designed to move automatic ga- tes and doors in commercial or residential buildings accessed by vehicles and persons”, and as such, the system must be...
  • Page 2 COMPONENTS OF KIT KIT/30F KIT/39F Motors MT/30/2 = KIT/30F MT/38/1 = KIT/39F CR/41 Electronic control unit with built-in receiver OG/62 2-channel minitransmitter with marsupium support M/10 Electric key P/10 Pair of impact-resistant photocells RZ/20 F Flashing light with built- in antenna, without internal circuit for flashing RZ/99...
  • Page 3 SYSTEM TYPE RG58 2 X 1,5 3 x 0,5 2 x 0,5 3 x 1,5 4 x 1,5 230V 4 x 1,5 4 x 0,5 2 x 0,5 4 x 0,5 MT/30/2, MT/38/1 gearmotor M/10 electric key CR/41 electronic control unit with built-in receiver Pair of P/10 photocells OG/62 2-channel minitransmitter RZ/20 F Flashing light with antenna...
  • Page 4 BEFORE INSTALLING THE MOTORS 1- Ensure perfect right angles of the gate hinges to enable totally smooth and balanced swing gate movement. Otherwise the motor may be damaged when subject to much higher levels of resistance with respect to those specified for intended use. 2- In the maximum gate opening and closing positions, check that two sturdy travel stops are anchored to the ground to block the gate leafs at the end of travel Fig.
  • Page 5 5) Choose the opening angle and calculate distances B and C, -Fig. 4 Fig. 5 and table for bracket positioning. The values in the grey band are recommended. The brackets can be resized (shortened or lengthened) according to assembly requirements, and observing distances B and C. N.B.
  • Page 6 8- Level the motor and tighten all screws and bolts fully down. Fig. 8. Fig. 8 9- With the aid of a 17 mm wrench, turn the half-nut on the mobile pin through half a turn to release the motors. Fig. 9. Check that movement is smooth.
  • Page 7 CR/41 CONTROL UNIT INSTALLATION CONTROL UNIT POSITIONING Position the equipment in the vicinity of the gate, to minimise the length of cables for connection to the rest of the system. For further protection against atmospheric agents, position the control unit under a canopy or for improved protection in an enclosure also fitted with two lateral walls.
  • Page 8 WALL-MOUNTING THE CONTROL UNIT Position the equipment in the vicinity of the gate, so that the length of the cables for connection to the rest of the system are as short as possible. Ø 6 ÷ 8 mm Secure the control unit with the cable routing holes facing downwards.
  • Page 9: Wiring Diagram

    23 - 24 RECEIVER 24=ANTENNA) ANTENNA ELECTRIC LOCK 12Vac 15VA max output for the direct command electric lock SERAI M/83/1. To 25 - 26 COMMAND reduce the noise it is possible to add a bridge rectifier as per diagram * PHOTOCELL...
  • Page 10 MOTOR FORCE ADJUSTMENT The motor force is adjusted by varying the power supply voltage via the “Power” potentiometer on the SERAI CR/41 control unit. In any event, installation must be in full observance with current standards governing power-operated gates; the installer is responsible for the system and operation in compliance with...
  • Page 11 SETTINGS OF EACH MICROSWITCH WARNING: Microswitches must only be adjusted when the control unit is disconnected from the power supply; any new microswitch settings are applied on subsequent start-up. After making new settings on microswitches, we recommend repeating the work time programming procedure (see control unit programming).
  • Page 12 MICROSWITCH DESCRIPTION OF OPERATION OPERATION SETTINGS SW 1 SW 2 - A start command sent during opening is ignored, while during the gate open pause causes closure. start - A start command sent during closing causes the gate to stop for STEP-STEP 2”...
  • Page 13 CONTROL UNIT PROGRAMMING Before proceeding with the programming, check that the system is equipped with all the electrical and safety devices (buttons, photocells, flashing lights, etc.), and that these are all connected. Ensure they all operate correctly: All the indicator LEDs for the NC inputs (stop, photocells, etc.) are lit. All the indicator LEDs for the NO inputs (start, pedestrian) are off.
  • Page 14 WORK AND DECELERATION TIME PROGRAMMING FOR SINGLE LEAF GATES (DIP1 SW1 ON) With the control unit powered and the gate closed, press the A (SET) key once to enter the programming mode. The DL10 LED starts flashing to indicate that the control unit is in the programming mode. Press the key C (WORK) once to start the opening phase of motor M1.
  • Page 15 RADIO CONTROL CODE LEARNING The electronic board incorporates a 433.92 MHz 2-channel radio receiver which allows remote gate control via either the OG/02 and OG/04 series microswitch-operated radio controls, or the self-learning radio controls from the following series: OG/62, OG/64, OG/28, OG/48, OG/52, OG/54, OG/82/1 and OG/84. Both channels are used solely for gate control;...
  • Page 16 EXPANDING THE NUMBER OF MINI TRANSMITTERS If the 32 mini transmitters storable in the built-in receiver are not sufficient, they can be increased by fitting the SOG/4A receiver (which takes the number of mini transmitters up to 40), with the optional addition of the SOG/2A expansion bo- ard (which takes the number of mini transmitters up to 794).
  • Page 17 P/10 PHOTOCELLS DIMENSIONS POSITION ALIGNMENT 70 mm 40 mm INSTALLATION CONNECTIONS THE CONTACT POSITION REFERS TO WHEN THE RECEIVER IS ENERGIZED Ø 6mm RECEIVER TRANSMITTER Ø 3.5mm The cable routing hole must be sized exactly for the cable RELAY OUTPUT POWER SUPPLY POWER SUPPLY to be passed through and no more...
  • Page 18 TERMS OF GUARANTEE The company reserves the right to make modifications to the equipment without prior notice thereof. SERAI products are covered by a standard guarantee with a term of 24 months. Coverage starts on the date on which the tax document constituting proof of purchase is issued and guarantee services shall be provided on the company's premises at Legnaro - PD - or at the Authorised Service Centres.

This manual is also suitable for:

Kit/39 f

Table of Contents

Save PDF