Bosch Climate 5000 AA Series Installation Manual page 10

Inverter one-two/one-three/one-four/one-five split-type air conditioner / heat pump
Hide thumbs Also See for Climate 5000 AA Series:
Table of Contents

Advertisement

1 0 | Bosch Climate 5000 AA Series Inverter Multi Split-Type Air Conditioner/ Heat Pump
Split type outdoor unit mounting dimensions
Dimensions [in.]
Outdoor Unit
W x H x D
BMS500-AAM018-
33.3x14.3x27.6
1CSXXA
BMS500-AAM027-
37.2x16.1x31.9
1CSXXA
BMS500-AAM036-
37.2x16.1x31.9
1CSXXA
BMS500-AAM048-
37.5x16.3x52.5
1CSXXA
Table 4
W
D
Figure 7
Data subject to change
Mounting Dimensions
[in. (mm)]
Distance A
Distance B
21.3 (540)
13.8 (350)
26.5 (673)
15.9 (403)
26.5 (673)
15.9 (403)
25.0 (634)
15.9 (404)
H
W
H
A
B
Row of series installation
The relations between H, A and L are as follows:
L
L ≤ 1/2H
L ≤ H
1/2H < L ≤ H
L > H
Table 5
H
Figure 8
The minimum distance between the outdoor unit and walls described
in the installation guide does not apply to airtight rooms. Be sure to keep
the unit unobstructed in at least two of the three directions (M, N, P) (See
Fig. 9)
M
N
Figure 9
Installation Manual
A
9.8" / 25 cm or more
11.8" / 30 cm or more
Can not be installed
P
01.2017 | Bosch Thermotechnology Corp.
L

Hide quick links:

Advertisement

Table of Contents
loading