Page 1
Käyttöohje ja takuu Bedieningshandleiding en garantieverklaring Instruções de utilização e declaração de garantia Οδηγίες χειρισμού και εγγύηση Instrukcja obsługi i deklaracja gwarancji seca gmbh & co. kg. Medizinische Waagen und Messsysteme Kullanım kılavuzu ve garanti beyanı Hammer Steindamm 9-25 22089 Hamburg...
Page 3
It In addition to determining weight conven- is easy to operate and the large display is tionally, the seca 808 can also calculate easy to read. Body Mass Index and body composition 2.
– If a load greater than 150 kg or 330.6 lb is placed on the scale, appears in St0P – Stand on the scale and keep still. the display. Once weight has been determined, the Automatic switch-off/economy mode The scale switches off automatically after 20 seconds. Model 808...
Storing personal data The seca 808 can store personal data for up to four different people. In addition, it is pos- sible to perform a measurement in so-called Guest Mode (see “Measuring in Guest Mode”...
Page 6
SET key. Measuring with automatic person recognition The seca 808 can use the weight to recognise whether the person standing on the scale matches one of the stored sets of data in the four people memories. So it is not always necessary to bend down to switch on the scale using one of the keys.
Measuring in Guest Mode If all personal memories are already occupied, or if you would like to obtain one-off values for BMI, body fat and body water for another person, you can perform the measurement in so-called Guest Mode.: – Switch on the scale by pressing the MALE ATHLETIC: male and athletic, MENU and SET keys simultaneously.
Clean the surface and the housing as required using a domestic cleaning agent or commer- cially-available disinfectant. Follow the manufacturer’s instructions. Under no circumstances use abrasive or acid cleaners, white spirit, benzene or the like for cleaning. Such substances can damage the high-quality surfaces. Model 808...
Page 9
7. What do I do if… … no weight display comes on? – Is the scale switched on? – Check the batteries. 0. 0 … does not appear before weighing? – Start the scale again after it switches off automatically – there must not be any load on the scale –...
4.0 to 80.0 % in 0.1 % increments 100 to 220 cm in 1 cm increments Height 39.5 inches to 86.5 inches in 0.5 inch increments Battery Power supply 4 type AAA 1.5 V batteries Batteries greater than ±0.6 % Weighing precision Model 808...
No further oured if the equipment is opened by per- claims can be entertained. The costs of sons not expressly authorised by seca to transport in both directions will be borne do so. by the customer should the equipment be...