mr. steam AirTempo 104232SQ Installation, Operation & Maintenance Manual

Advertisement

Quick Links

.
mr
steam
®
Installation, Operating & Maintenance Instructions
________________________________________________________________________________________________
A i r Te m p o
®
Wireless
Touch Control with Steamhead
Installation, Operation & Maintenance Manual
®
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AirTempo 104232SQ and is the answer not in the manual?

Questions and answers

Summary of Contents for mr. steam AirTempo 104232SQ

  • Page 1 steam ® Installation, Operating & Maintenance Instructions ________________________________________________________________________________________________ A i r Te m p o ® Wireless Touch Control with Steamhead Installation, Operation & Maintenance Manual ®...
  • Page 2: Important Safety Instructions

    steam ® Installation, Operating & Maintenance Instructions ________________________________________________________________________________________________ When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: IMPORTANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ALL INSTRUCTIONS thermia). Limit your use of steam to 10-15 HYPERTHERMIA occurs when the internal minutes until you are certain of your body’s...
  • Page 3: Table Of Contents

    steam ® Installation, Operating & Maintenance Instructions ________________________________________________________________________________________________ Table of Contents: READ ME FIRST! Important Safety Instructions ........2 As you follow these instructions, you will notice warning and WARNING caution symbols. This blocked information is important for the safe and ef- Before Installing ............4 ficient installation and operation of the steambath system.
  • Page 4: Before Installing

    steam ® Installation Instructions ________________________________________________________________________________________________ Before Installing room a Remote Temperature Probe (PN MSTS) must be installed inside the steam Carefully inspect the control and packaging for shipping damage. In the event of room per instructions for the Remote Temperature Probe. Failure to install according to shipping damage, please contact the carrier for claim information.
  • Page 5: Dimensional Information

    steam ® Installation Instructions ________________________________________________________________________________________________ Dimensional Information for the AirTempo 1-5/8” 7/8” BOX CONTENTS: 3/4” 3-5/8” 4-7/8” 3-5/8” AirTempo Wireless Receiver (shown with decorative trim) Drawings for illustrative purposes only...
  • Page 6 steam ® Installation Instructions ________________________________________________________________________________________________ Installation Instructions for AirTempo STEP 1 Determine the desired installation location of the control. The AirTempo controls are designed to be installed inside or outside the steam room as a matter of personal preference. If the control is installed outside the steam room a Remote Temperature Probe part number MSTS must be installed inside the steam room.
  • Page 7: Important Note

    steam ® Installation Instructions ________________________________________________________________________________________________ STEP 2 The AirTempo Flush mount components are sold separately (104232DR & 104232SQ). Contact a Surface Mount AirTempo Use the screw and anchor provided to secure the bayonet to the IMPORTANT NOTE: wall as required for rough or uneven wall surfaces. The surface mount bayonet supports the weight of the AirTempo control.
  • Page 8: Wireless Receiver Installation

    steam ® Installation Instructions ________________________________________________________________________________________________ Wireless Receiver Installation The control can be located up to 60 feet from the wireless Steam receiver. Construction materials may affect the communica- Generator tion between the control and the receiver. Test the range of the AirTempo.
  • Page 9: Installation: Surface Flush Mount

    steam ® Installation, Operating & Maintenance Instructions ________________________________________________________________________________________________ IMPORTANT NOTE: Do not rest the dongle on the steam generator, the metal case of the generator may shield the RF signal. The control features an integral temperature sensor. AirTempo Control Locate the control in a location representative of the Surface or Flush Mount desired steam bathing temperatures.
  • Page 10: Installing The Remote Temperature Probe

    steam ® Installation Instructions ________________________________________________________________________________________________ Installing the Remote Temperature Probe (PN: MSTS) Locating the MSTS near the steamhead or near direct steam The Remote Temperature Probe is required when the CAUTION emissions may result in poor steam room temperature control. AirTempo control is installed outside the steam room.
  • Page 11 steam ® Installation Instructions ________________________________________________________________________________________________ DIAGRAM 1 Temperature Probe Connection Knock-Out Temperature Probe Cable (30 feet) Temperature Sensor Probe Mr.Steam Steam Generator (shown with cover removed and NOT installed) Drawings for Illustrative Purposes Only.
  • Page 12 steam ® Installation Instructions ________________________________________________________________________________________________ Insure a minimum of 1/4” of the temperature probe is exposed 5. Route the end of the probe cable with the temperature probe WARNING to the air. Failure to do so may interfere with the ability to sense tempera- through the wall into the steam room as shown in Diagram 2.
  • Page 13: Airtempo Operating Instructions

    steam ® Operating Instructions ________________________________________________________________________________________________ AirTempo Operating Instructions Diagram 1 ON/OFF Diagram 1 The AirTempo features programmable temperature control, programmable time duration, AromaSteam Press the ON/OFF key for 1 second to start the ON/OFF, ChromaSteam control and two personal ® settings.
  • Page 14: Setting The Temperature

    steam ® Operating Instructions ________________________________________________________________________________________________ Diagram 3 SETTING THE TEMPERATURE Diagram 3: Press TEMP key to set the desired temperature or display the temperature setting. The control is preset and will display a temperature setting of 110˚F (default setting). With the temperature displayed, press the LEFT or RIGHT arrows to set the desired temperature (80°F to 120°F) in one degree increments.
  • Page 15 steam ® Operating Instructions ________________________________________________________________________________________________ (˚F/˚C) AROMASTEAM CHANGING THE TEMPERATURE UNITS When the generator is ON, press and hold the TEMP key for 10 The AromaSteam is an optional accessory that automatically seconds. The temperature units will toggle to Fahrenheit (F) or injects aromatic oil into the steam.
  • Page 16: Battery Replacement

    steam ® Maintenance Instructions ________________________________________________________________________________________________ Battery Replacement The batteries in AirTempo will need periodic replacement. Both batteries should be replaced at the same time with new CR2450 coin cell batteries. CHOKE HAZARD. The batteries and battery doors are small WARNING Batteries pieces, keep out of reach of children.
  • Page 17: System Status Codes

    steam ® Maintenance Instructions ________________________________________________________________________________________________ System Status Codes Care Tips for AirTempo Controls and Steamheads The AirTempo may display a status code if the steam system is not 1. Use only mild soap and water on a soft cloth to clean functioning correctly.
  • Page 18 steam ® Maintenance Instructions ________________________________________________________________________________________________ FCC/Industry Canada Two Part Statement: This device complies with FCC Part 15 and Industry Canada license exempt NOTE: This equipment has been tested and found to comply with the limits RSS standard(s). Operation is subject to the following two conditions: (1) this for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 19: Parts List

    steam ® Maintenance Instructions ________________________________________________________________________________________________ Parts List: ITEM # DESCRIPTION USED ON 104208BK Electronic Assembly Black 104208WH Electronic Assembly White 104209 Retention Ring (AirTempo Flush) Flush Mount 104210 Flush Mount Box (AirTempo Flush) Flush Mount 104211 Surface Mount Holder (AirTempo Surface) Surface Mount 104212 Wireless Receiver 104213XX Round Bezel (AirTempo Flush)
  • Page 20: Glass Mount Mask

    Glass Mount Mask...
  • Page 21 Glass Mount Mask...
  • Page 22: Flush Mount Installation

    steam ® Installation Instructions ________________________________________________________________________________________________ Flush Mount AirTempo IMPORTANT NOTE: Flush mount components are sold separately (104232RD Do not oversize or undersize the cutout. Ensure the template is level before cutting the hole. Magnet IMPORTANT NOTE: Do not apply excessive amounts of moisture seal.
  • Page 23: Flush Mount Template

    steam ® ________________________________________________________________________________________________ Place the electronic assembly into the decorative Template bezel as shown. The retention ring snaps onto the For Flush Mount Kit Installation assembly from behind. The 3 piece assembly can then in the box that will hold the control in place.
  • Page 24 www.mrsteam.com Products, information and specifications are subject to change without notice. For more information call Sales & Support at: 1.800.76.STEAM 1.800.72.STEAM (East Coast) (West Coast) mr.steam Sussman-Automatic Corporation ® hello@mrsteam.com www.mrsteam.com 43-20 34th Street, Long island City NY 11101 9410 S. La Cienega Blvd., Inglewood CA 90301 : 718 472 3256 : 310 216 2944 800 767 8326...

This manual is also suitable for:

Airtempo 104232rd

Table of Contents