Troubleshooting : Heart Rate Reading - Life Fitness M051-00K99-0004 Operation Manual

Elevation series
Table of Contents

Advertisement

Troubleshooting -
Malfunction
Heart rate reading
is initially detected
and functioning
normally but then
is lost.
Heart rate readings
are abnormally
elevated.
Heart rate reading
is erratic or
absent entirely.
34
Heart Rate Reading
Probable Cause
Use of personal electronic devices, such as
cell phones and portable MP3 players, causes
external noise interference.
Equipment is in close proximity to other
sources of noise such as audio/video equip-
ment, fans, two way radios, and high voltage/
high current power lines.
Television sets and/or antennas, cell phones,
computers, cars, high voltage power lines, mo-
tor driven exercise equipment , and another
heart rate transmitter within 3 ft. (0.9 m) gener-
ate electromagnetic interference.
Chest strap transmitter electrodes are not wet
enough to pick up accurate heart rate read-
ings.
Chest strap transmitter electrodes are not lay-
ing flat against the skin.
Chest strap transmitter needs cleaning.
Chest strap transmitter is not within 3 ft. (0.9
m) of the heart rate receiver.
Polar telemetry heart rate chest strap battery is
depleted.
Polar telemetry heart rate chest strap did not
lock in with the heart rate receiver.
Corrective Action
Remove the source of noise or reposition the
exercise equipment. Keep hand movement
to a minimum on the sensors. Make sure
there is good contact between the hands
and heart rate sensors. Make sure hands are
not damp or moist.
Move the product a few inches away from
the probable cause, or move the probable
cause a few inches away from the product,
until the heart rate readings are accurate.
Wet the chest strap transmitter electrodes
(see The Optional Polar
Rate Chest Strap).
Ensure the chest strap transmitter electrodes
are laying flat against the skin (see The
Optional Polar
®
Telemetry Heart Rate Chest
Strap).
Wash the chest strap transmitter with mild
soap and water.
Make sure the chest strap transmitter is
within 3 ft. (0.9 m) of the heart rate receiver.
Contact Life Fitness Customer Support Ser-
vices for instructions on how to have the Po-
lar telemetry heart rate chest strap replaced.
Make sure the Polar telemetry heart rate
chest strap is properly attached to the user's
chest and move closer to the heart rate
receiver inside the console (Non-treads) or
the activity zone (Treadmills). Wait up to 10
seconds for the heart rate to display on the
console. The overall range of the heart rate
strap is approximately 3 ft. (0.9 m) after it
communicates with the receiver. The strap
must be 1.5 - 2 ft. (0.5 - 0.6 m) away from the
receiver in order to start communicating.
When the display shows a heart rate value
stay within 3 ft. (0.9 m).
Notes:
1. Ensure proper adherence of the Polar
telemetry heart rate chest strap to user's
chest.
2. Ensure proper conductivity between the
electrodes and user's chest.
Telemetry Heart
®