WATER SOURCE HEAT PUMP CEILING CASSETTE
SPLIT TYPE AIR CONDITIONER (A SERIES)
© 2006 McQuay International
INSTALLATION MANUAL
IM-5CKWSAR-0506(0)-McQuay
Group: WSHP
Part Number: A08019027750
Date: MAY 2006

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WSHP and is the answer not in the manual?

Questions and answers

Summary of Contents for McQuay WSHP

  • Page 1 INSTALLATION MANUAL IM-5CKWSAR-0506(0)-McQuay Group: WSHP Part Number: A08019027750 Date: MAY 2006 WATER SOURCE HEAT PUMP CEILING CASSETTE SPLIT TYPE AIR CONDITIONER (A SERIES) © 2006 McQuay International...
  • Page 2: Outline And Dimensions

    (32,2) (14,3) (13,2) (1,1) (36,6) (36,6) (25,2) (24,5) (21,9) (21,9) 40AR 50AR MODEL SELECTION 08A01 CKA APLWS2 BOARD LAYOUT HIGH HOT KEEP MODEL TRANSFORMER 1 2 3 REFER TO TABLE Model Selection Table System Jumper Position SINGLE WSHP (Default) TANDEM...
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS ! CAUTION ! WARNING Please take note of the following important points • Installation and maintenance shall be performed by quali- when installing. fied persons who are familiar with local code and • Do not install the unit where leakage of flammable gas regulation, and experienced with this type of appliance.
  • Page 4 3. Unit Hanging 5. Drain Test Feed Water Main Drain Pipe Indoor Unit Flexible Drain Hose • Connect the main drain pipe to the flexible drain. Ceiling Board • Feed water from flexible drain hose to check the piping for leakage. 35.0 mm •...
  • Page 5: Refrigerant Piping Work

    REFRIGERANT PIPING WORK Refrigerant piping is important in particular. Refrigerant cycle of the split air conditioner is realized by the perfect piping work. 1. Piping Length And Elevation • If the piping is too long, both the capacity and reliability of unit will drop. •...
  • Page 6: Electrical Data

    ELECTRICAL DATA R410A – Heat Pump Model 5CKWS20AR 5CKWS25AR 5CKWS30AR Coupling Unit 5WSS16AR 5WSS20AR 5WSS25AR 5WSS30AR Power Supply V-Ph-Hz 230-1-50 Indoor Unit Rated Voltage Range 220-240 Capacitor µF Nominal Power Input Nominal Current Input 0.53 0.61 0.67 Model 5CKWS40AR 5CKWS50AR Coupling Unit 5WSS40AR 5WSS50AR...
  • Page 7: Special Precautions When Dealing With R410A Unit

    5CKWS40/50AR <> 5WSS40/50AR Model 5CKWS40AR 5CKWS50AR Water Outlet Sensor Coupling Unit 5WSS40AR 5WSS50AR Voltage range ** 380-415V/3Ph/50Hz+N+E Interconnection Cable Power supply cable size* Terminal Block COMP Number of wire Terminal Block (5WSS-AR) Fan Coil Unit Interconnection cable size* mm COMP1 Number of wire COMP2 Recommended fuse...
  • Page 8: Accessory Parts

    3. Charge Operation Liquid side Fan Coil Unit Water Source This operation must be done by using a gas cylinder and a precise weighing Heat Pump Unit Discharge Valve machine. The additional charge is topped-up into the water source heat pump Open unit using the suction valve via the service port.
  • Page 9: Service And Maintenance

    The manufacturer reserves right to revise any of the specification and design contain herein at any time without prior notification. OYL MANUFACTURING COMPANY SDN. BHD. JALAN PENGAPIT 15/19, P.O. BOX 7072, 40702 SHAH ALAM, SELANGOR DARUL EHSAN, MALAYSIA. © 2006 McQuay International...