Pentair SN Series Owner's Manual
Pentair SN Series Owner's Manual

Pentair SN Series Owner's Manual

Shallow well jet pumps
Hide thumbs Also See for SN Series:

Advertisement

Installation/Operation/Parts
For further operating, installation,
or maintenance assistance:
Call 888-782-7483
English ............................ Pages 2-14
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.STA-RITE.COM
PH: 888-782-7483
© 2012 Pentair, Inc. All Rights Reserved.
SN Series / Série SN / Serie SN
HN Series / Série HN / Serie HN
Installation/Fonctionnement/
Pièces
Pour plus de renseignements
concernant l'utilisation,
l'installation ou l'entretien,
composer le 888-782-7483
Français ........................ Pages 15-27
OWNER'S MANUAL
Shallow Well Jet Pumps
NOTICE D'UTILISATION
Pompes à éjecteur pour
puits peu profonds
MANUAL DEL PROPIETARIO
Bombas tipo "Jet" para
pozos poco profundos
2400 0496 NF
Instalación/Operación/Piezas
Para mayor información sobre el
funcionamiento, instalación o
mantenimiento de la bomba:
llame al 888-782-7483
Español ....................... Paginas 28-40
S376 (11/05/12)

Advertisement

Table of Contents
loading

Summary of Contents for Pentair SN Series

  • Page 1 Pompes à éjecteur pour puits peu profonds MANUAL DEL PROPIETARIO Bombas tipo “Jet” para pozos poco profundos 2400 0496 NF SN Series / Série SN / Serie SN HN Series / Série HN / Serie HN Installation/Operation/Parts Installation/Fonctionnement/ Instalación/Operación/Piezas Pièces For further operating, installation, Para mayor información sobre el...
  • Page 2: General Safety

    Safety READ AND FOLLOW ELECTRICAL SAFETY SAFETY INSTRUCTIONS! Capacitor voltage may be hazardous. To discharge motor capacitor, hold insulated handle This is the safety alert symbol. When you see this screwdriver BY THE HANDLE and short capacitor terminals symbol on your pump or in this manual, look for one of the together.
  • Page 3: Table Of Contents

    Table of Contents Page General Safety .....................2 Warranty......................3 Installation (Well Pumps) .................4, 5 Connecting Discharge Piping................6 Pressure Booster System ..................7 Electrical ......................8, 9 Preparing To Start The Pump ................10 Repair Parts ....................11-13 Troubleshooting ....................14 Limited Warranty STA-RITE warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below.
  • Page 4: Installation (Well Pumps)

    Installation REPLACING AN OLD PUMP 2. Mount the pump as close to the well as possible. 3. Use the fewest possible fittings (especially elbows) Hazardous voltage. Disconnect power to when connecting the pipe from the well point to pump before working on pump or motor. the pump suction port.
  • Page 5 Installation 4. Install a priming tee, priming plug, and suction pipe 2. Assemble a foot valve and suction pipe (Figure 3). to the pump (see Figure 2). Connect the pipe from Make sure that the foot valve works freely. Use PTFE the well to the pump suction port, using the fewest pipe thread sealant tape on threaded pipe joints.
  • Page 6: Connecting Discharge Piping

    Discharge Pipe and Pressure Tank Connections PRE-CHARGE TANk CONNECTION STANDARD TANk CONNECTION (FIGURE 4) (FIGURE 5) 1. Install two tees in the pump discharge port (see 1. Install one tee in the pump discharge port Figure 4). The pipe size must be at least as large as (see Figure 5).
  • Page 7: Pressure Booster System

    Typical Pressure Booster System INSTALLATION Gate Valve Pressure and Union Gauge Water Out for Service to Household Hazardous pressure. Install a relief valve as Access Low Pressure shown capable of passing entire pump flow at 75 PSI. Cutoff Switch Pump body may explode if internal pressure exceeds 75 Check Valves PSI.
  • Page 8: Electrical

    Electrical Disconnect power before working on pump, motor, pressure switch, or wiring. MOTOR SWITCH SETTINGS Dial Type voltage Selector To change to 115 volts: Dual-voltage motors (motors that can operate at either 115 or 230 volts), are set at the factory to 230 volts. Do not 1.
  • Page 9 Electrical WIRING CONNECTIONS 2. There must be a solid metal connection between the pressure switch and the motor for motor grounding Fire hazard. Incorrect voltage can cause a protection. If the pressure switch is not connected fire or seriously damage the motor and voids the to the motor, connect the green ground screw in the warranty.
  • Page 10: Preparing To Start The Pump

    Preparing to Start the Pump PREPARING TO START THE PUMP NOZZLE CLEAN OUT (LOW PRESSURE) Never run pump dry. Running pump with- Use an icepick or brad awl to clean out the nozzle – out water may cause pump to overheat, damaging seal 3/16”...
  • Page 11: Repair Parts

    Repair Parts Exploded view SN Series - 1/2 HP (AVC Port) 2352 0396 REPAIR PARTS LIST: SN Series, 1/2 HP Model and Horsepower Part SNC-L SNC-HF25L SNC-5L Description Used 1/2 HP 1/2 HP 1/2 HP Motor J218-582APKG J218-582APKG J218-582APKG #§2...
  • Page 12: Exploded View

    Repair Parts Exploded view SN Series - 3/4 thru 1-1/2 HP (AVC Port) 2352 0396 REPAIR PARTS LIST: SN Series, 3/4 thru 1-1/2 HP Model and Horsepower Part SND-L SNE-L SNF-L Description Used 3/4 HP 1 HP 1-1/2 HP Motor...
  • Page 13 Repair Parts Exploded view HN Series - 1/2 thru 1-1/2 HP Nozzle Cleanout Port REPAIR PARTS LIST: HN Series, 1/2 thru 1-1/2 HP 2763 0197 HNC-L HNDX HND-L HNEX HNE-L HNFX Part Description Qty. 1/2 HP 3/4 HP 3/4 HP 1 HP 1 HP 1-1/2 HP...
  • Page 14: Troubleshooting

    Troubleshooting SYMPTOM POSSIBLE CAUSE(S) CORRECTIvE ACTION Motor will not run Disconnect switch is off Be sure switch is on. Fuse is blown or circuit breaker tripped Replace fuse or reset circuit breaker. Starting switch is defective DISCONNECT POWER; Replace starting switch. Wires at motor are loose, Refer to instructions on wiring (Page 8).