Door Lock Controlled With Dry Contact; Unlock Parameter Setting(Set On Monitor) - V-Tec DT601 User Manual

2-wire video outdoor station
Table of Contents

Advertisement

Door Lock Controlled with Dry Contact

Note:
1.
The external power supply must be used
according to the lock.
2.
The inside relay contact is restricted to AC or
DC 24V/1A.
3.
The jumper must be taken off before connecting.
4.
Setup the Unlock Mode of Monitor for
different lock types.
• Power-on-to-unlock type:Unlock Mode=0 (by
default)
• Power-off-to-unlock type:Unlock Mode=1

Unlock parameter setting(set on monitor)

• On main menu page, touch [Logo] icon to enter About page.
• When the screen stay in About page, press
seconds.
• A keypad is shown.
Refer to the followings:
Note:
1.must connect DT601(F)/ID/FE correctly before setting.
2.the parameter will be saved in DT601(F)/ID/FE automatically, so you need only set on one monitor.
3.Here we take DT47MG(the monitor) for example, please refer to the corresponding user manual.
-6-
UNLOCK button on front panel and hold for 2
00:10
DS-1
About
Local Address
00.00
Video Standard
AUTO
System Verson
00.01.00
Display Driver
1.0
Font
1.0
UI
1.0
Take off the Jumper
BUS
PL
S +
S-
POWER
SUPPLY
INSTALLER SETUP
_
? + OK: Help Menu
@ + OK: Address Setting Menu
LOCK
123