4. ELECTRICAL WIRING DIAGRAMS
PLFY-P08, 12, 15, 18, 24, 30, 36NBMU-E2
A.B
GRILLE
ON
MV
MV
MV
MV
OFF
1 2 3 4 5 6 7 8 9 10
M
M
M
M
SW12 SW11
10ths
5
5
5
5
DIGIT
20
18
16
14
12
10
8
6
4
2
19
17
15
13
11
9
7
5
3
1
VANE
CNV
I-SEE SENSOR MOTOR
(WHT)
CN6Y
1
(RED)
6
MA REMOCON
CN3A
(BLU)
1
3
I-SEE SENSOR
CN4Y
(WHT)
1
4
LEV
CN60
1
(WHT)
6
CN52
CN51
1
(GRN)
5
1
(WHT)
5
4
5
6
M
I-SEE
SENSOR
MT
M
I-SEE SENSOR CORNER PANEL
(OPTION PART)
LEV
NOTES:
1. At servicing for outdoor unit, always follow the wiring diagram of outdoor unit.
2. In case of using MA-Remote controller, please connect to TB15. (Remote controller wire is non-polar.)
3. In case of using M-NET, please connect to TB5. (Transmission line is non-polar.)
4. Symbol [S] of TB5 is the shield wire connection.
5. Symbols used in wiring diagram above are,
6. The setting of the SW2 dip switches differs in the capacity. For the detail, refer to fig <*1>.
*2. Use copper supply wires.
*2. Utilisez des fils d'alimentation en cuivre.
SYMBOL
NAME
I. B
INDOOR CONTROLLER BOARD
CN24
CONNECTOR
EXTERNAL HEATER
CN27
DAMPER
CN32
REMOTE SWITCH
CN51
CENTRALLY CONTROL
CN52
REMOTE INDICATION
CN105
IT TERMINAL
FUSE
FUSE (T6.3AL250V)
POWER SUPPLY (I. B)
LED1
LED2
POWER SUPPLY (I. B)
CAPACITY CODE
SW2
SWITCH
SW3
MODE SELECTION
SW4
MODEL SELECTION
SWE
DRAIN PUMP (TEST MODE)
X1
AUX. RELAY
DRAIN PUMP
LED on indoor board for service
Mark
Meaning
Main Power supply (Indoor unit:208-230V)
LED1
Main power supply
power on → lamp is lit
Power supply for
Power supply for MA-Remote controller
LED2
MA-Remote controller
on → lamp is lit
PLFY-10
PLFY-P-NCMU-ER4, -NBMU-E2 (November 2015)
is the switch position.
4
(RED)
MODELS
ADDRESS
CN43
P08
SWA
SWB
1
8
SW1
3
2
2
3
1
4
P12
(RED)
ADDRESS
SW14
CN82
SWC
P15
2
1
1s
BRANCH
1
P18
DIGIT
No.
8
4
CN32
J42 J41
(WHT)
1
3
1
8
1
4
Pair No.
ADDRESS
ADDRESS
CN42
CN81
(RED)
(RED)
LED2
1
CN105
WIRELESS
(RED)
CN90
(WHT)
1
9
LIQUID/GAS
CN44
CN41
(WHT)
(WHT)
1
4
1
4
9
TB15
2
TO MA-REMOTE
BZ
1
CNB
CONTROLLER
2
8.7-13V DC
LED2
SW1
LED1
SW2
RU
TH22
TH23
W.B
(OPTION PART)
: terminal block,
SYMBOL
DP
DRAIN PUMP
FS
DRAIN FLOAT SWITCH
LEV
LINEAR EXPANSION VALVE
MF
FAN MOTOR
MV
VANE MOTOR
TB2
TERMINAL
POWER SUPPLY
TB5
BLOCK
TRANSMISSION
TB15
MA-REMOTE CONTROLLER
TH21
THERMISTOR
ROOM TEMP. DETECTION
(32°F/15k , 77°F/5.4k )
TH22
PIPE TEMP. DETECTION / LIQUID
(32°F/15k , 77°F/5.4k )
TH23
PIPE TEMP. DETECTION / GAS
(32°F/15k , 77°F/5.4k )
Function
<*1>
SW2
MODELS
SW2
ON
ON
P24
OFF
OFF
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
P30
OFF
OFF
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
P36
OFF
OFF
1 2 3 4 5 6
1 2 3 4 5 6
2
ON
OFF
1 2 3 4 5 6
See fig: *1
SW3
SW4
SW2
ON
ON
2 1
OFF
OFF
M-NET
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5
1 2 3 4 5 6
CN2M
(BLU)
SWE
DC311~339V
OFF
ON
RECTIFICATION
5
CN24
CN25
1
3
(YLW)
(WHT)
CN3G
1
2
1
2
(BLK)
LED1
INTAKE
FAN
FLOAT SW
CN27
CN20
CNMF
CN4F
(RED)
(RED)
(WHT)
(WHT)
1
4
1
2
1
2
7
4
1
MS
3~
MF
*Be sure to turn off the source power
and then disconnect fan motor connector.
FS
TH21
(Failure to do so will cause trouble in Fan motor)
: connecter.
NAME
SYMBOL
ADDRESS BOARD
A. B
SWA
SWITCH
SWB
SWC
SW1
SW11
SW12
SW14
OPTION PART
PCB FOR WIRELESS REMOTE CONTROLLER
W.B
BZ
BUZZER
LED1
LED (OPERATION INDICATION : GREEN)
LED2
LED (PREPARATION FOR HEATING : ORANGE)
RECEVING UNIT
RU
SW1
EMERGENCY OPERATION (HEAT / DOWN)
SW2
EMERGENCY OPERATION (COOL / UP)
MT
I-SEE SENSOR MOTOR
POWER SUPPLY
~/N 208-230V 60Hz
TB5
TO OUTDOOR UNIT
M1
BC CONTROLLER
BREAKER
M2
REMOTE CONTROLLER
(16A)
S
24-30V DC
(SHIELD)
FUSE(16A)
*2
TB2
RED
PULL BOX
L1
BLU
L2
GRN/YLW
TO NEXT
GR
INDOOR UNIT
I.B
1 3 5
CND
(BLK)
FUSE
X1
CNAC
(WHT)
D.U.M
3
1
3
1
CNP
(BLU)
M
1~
DP
NAME
CEILING HEIGHT SELECTOR
DISCHARGE OUTLET NUMBER
SELECTOR
OPTION SELECTOR
MODE SELECTION
ADDRESS SETTING 1s DIGIT
ADDRESS SETTING 10ths DIGIT
BRANCH NO.