Checking Level Accuracy; Checking Vertical Accuracy; Adjusting Level Accuracy; Troubleshooting - Agatec RL110 User Manual

Hide thumbs Also See for RL110:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
factory. It is recommended to check your laser for accuracy upon receipt
and periodically thereafter to ensure accuracy is maintained. If your laser
requires adjustment, contact the nearest authorized service center or
adjust the laser using the following procedure.
• Do not enter this mode or attempt adjustment unless you plan to change
the accuracy. Accuracy adjustment should only be performed by a
qualified individual that understands basic adjustment principles.

Checking level accuracy

To check the level accuracy of your laser, place the unit on a flat, level
surface or tripod approximately 30 meters (100 ft.) from a wall.
• Align the X-axis so that it is square to the wall. Allow the laser to self-
level completely (approximately one minute after the laser begins to
rotate). Then mark the position of the beam (Position 1).
• Rotate the laser 180°, allow it to self level and mark the opposite side
of the first axis (Position 2).
• Align the Y-axis by rotating the laser 90° so that this axis is now square
to the wall. Allow the laser to self- level completely, and then mark the
position of the beam (Position 3).
• Rotate the laser 180°, allow it to self level and mark the opposite side
of the Y-axis (Position 4).
• The laser is within its accuracy specification if the four marks are
within ± 3 mm (± 1/8") from the center.

Checking vertical accuracy

To check the vertical accuracy of your laser, place the unit in the laydown
position on a flat, level surface approximately 15-30 meters (50-100 ft.)
from a wall.
• Hang a plumb line on the wall.
• Move the laser until the vertical, rotating beam is aligned to the plumb line.
• If the rotating beam is not plumb, adjustment is necessary.

Adjusting level accuracy

If the accuracy checks may lead to a necessity of re-adjusting the unit, a
corresponding description of how to adjust the level accuracy can be
found online at www.agatec.com.
12

Troubleshooting

Symptom
Possible Causes and Solutions
The laser beam blinks,
The unit is most likely out of its 10%
but the unit will not
self-leveling range.
self-level or rotate.
• Check your set up and re-level the
tripod if necessary.
• If this does not solve the problem,
the laser should be returned to an
authorized service center for service.
The laser does not turn on.
The symptom may be caused by low or
dead batteries.
• Check or change the batteries.
• If not the batteries, the laser should be
returned to an authorized service center
for service.
The laser's distance is
Dirt may be reducing the output of the
reduced.
laser.
• Clean the windows of the laser and
receiver to improve distance.
• If not the windows, the laser should be
returned to an authorized service center
for service.
The IR Remote is not
Check for proper operation of the remote.
working.
• Check that the laser is turned on.
• The remote may be outside the usable
distance.
• Aim the remote more directly at the
laser for maximum distance.
• The remote's battery may be low.
The laser's receiver is not
Check for proper operation of the receiver.
functioning properly.
• The laser is not rotating. It is leveling or
in elevation alert.
• The laser is in scanning mode.
• The receiver may be outside the usable
distance.
• The receiver's battery may be low.
ALL three LED's are
The unit has been moved or pushed as HI
flashing in sequence.
was active. Press ON/OFF to restart the unit.
EN
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rl100 g

Table of Contents